| Specification |
Details |
| Continuous power at 25 °C |
250 VA |
| Continuous power at 40 °C |
175 W |
| Peak power |
400 W |
| AC output voltage |
230 Vac +/- 3 % |
| AC output frequency |
50 Hz or 60 Hz +/- 0.1 % |
| DC input voltage range |
18.4 - 34.0 Vdc |
| Low battery voltage shut down (adjustable) |
18.6 Vdc |
| Low battery voltage restart & alarm (adjustable) |
21.8 Vdc |
| Battery charged detection voltage (adjustable) |
28.0 Vdc |
| Max. efficiency |
88 % |
| Zero-load consumption |
5.2 W |
| Zero-load consumption in ECO mode |
1.3 W |
| Power limit for ECO mode |
adjustable via VictronConnect app |
| Technology |
Pulse Width Modulation (PWM) |
| Max. PV array voltage |
50 Vdc |
| Max. PV array current |
10 A |
| Max. PV array power |
500 W |
| Solar panel type |
72 cell solar panel or two 36 cell solar panels in series |
| PV array voltage to initiate battery charging |
voltage that is higher than battery voltage |
| Charging voltages |
adjustable via VictronConnect app |
| Temperature-compensated charging |
Yes, via an optional temperature sensor |
| Protection |
a – f |
| Operating temperature range |
(derate 1.25 % per °C above 40 °C) |
| Humidity |
max. 95 % |
| Bluetooth |
for remote monitoring and system integration |
| VE.Direct port |
for remote monitoring and system integration |
| Material |
steel chassis and plastic cover (blue Ral 5012) |
| Battery connection terminals |
screw terminals |
| Max. battery cable cross section |
10 mm² or AWG |
| PV connection terminals |
screw terminals |
| Max. PV cable cross section |
4 mm² or AWG 12 |
| AC output sockets |
IEC-320 (male plug included) |
| Protection class |
IP 21 |
| Weight |
2.4 kg / 5.3 lbs |
| Dimensions (h × w × d) |
3.4 × 6.5 × 10.2 inch |
| Remote on/off |
Yes, can be used for remotely turning unit on/off, or for battery temperature sensing. |
| Battery temperature sensor |
Use Temperature sensor QUA PMP GX Device or a Smart Battery Sense. |
| Automatic AC transfer switch |
Not built-in. Add a Filax 2 transfer switch, or use an inverter/charger instead. |
| Safety |
EN/IEC 60335-1 / EN/IEC 62109-1 |
| EMC |
IEC 61000-6-1 / IEC 61000-6-3 |
| Automotive directive |
ECE R10-4 EN 50498 |
| Nominal voltage |
24 V |
| Item number |
SIN241251100 |