Victron Isolation transformer 4500W 115/230V – galvanic isolation of shore powerThe Victron Isolation transformer 4500W 115/230V from Victron Energy provides galvanic isolation between shore power and the onboard installation. It stops galvanic corrosion on the hull and makes the shore connection safe.Advantages
Galvanic isolation: Breaks the connection to the harbor ground and stops galvanic corrosion on the hull.
Safe shore power: Protects both the installation and people in case of faults in the harbor grid.
Robust construction: Built for permanent operation in a humid environment.
Application
Shore power in boats, where galvanic corrosion must be avoided.
Adjustment between different grid voltages.
Safe separation of the vessel and the harbor grid.
Specifications
Specification
Details
AC input voltage
115 or 230 V
AC output
120 or 240 V
Frequency
50/60 Hz
Output current rating
17 A (115 V) / 8.5 A (230 V)
Soft start
Yes
Operating temperature range
-20 °C to 40 °C
Humidity
max. 95%, non-condensing
Transformer type
Toroidal (low noise, low weight), 1:1.05 ratio
Enclosure
aluminium (blue RAL 5012)
Protection class
IP21
Safety
EN 60076
Weight
12.7 kg
Dimensions (h × w × d)
375 × 214 × 135
Item number
ITR040452042
Download datasheet (PDF)
Victron Isolation Transformer 3600W 115/230V – galvanic isolation of shore powerThe Victron Isolation Transformer 3600W 115/230V from Victron Energy provides galvanic isolation between shore power and the onboard installation. It stops galvanic corrosion on the hull and makes the shore connection safe.Advantages
Galvanic isolation: Breaks the connection to the harbor's ground and stops galvanic corrosion on the hull.
Safe shore power: Protects both the system and personnel in case of faults in the harbor's grid.
Robust construction: Built for continuous operation in a humid environment.
Application
Shore power in boats where galvanic corrosion must be avoided.
Adjustment between different grid voltages.
Safe separation of the vessel and the harbor grid.
Specifications
Specification
Details
AC input voltage
115 or 230 V
AC output
120 or 240 V
Frequency
50/60 Hz
Output current rating
17 A (115 V) / 8.5 A (230 V)
Soft start
Yes
Operating temperature range
-20 °C to 40 °C
Humidity
max. 95%, non-condensing
Transformer type
Toroidal (low noise, low weight), 1:1.05 ratio
Enclosure
aluminum (blue RAL 5012)
Protection class
IP21
Safety
EN 60076
Weight
12.7 kg
Dimensions (h × w × d)
375 × 214 × 135
Part number
ITR040362042
Download datasheet (PDF)
Victron Isolation transformer 8000W 230V – galvanic isolation of shore powerThe Victron Isolation transformer 8000W 230V from Victron Energy provides galvanic isolation between shore power and the onboard installation. It stops galvanic corrosion on the hull and makes the shore connection safe.Advantages
Galvanic isolation: Breaks the connection to the harbor ground and stops galvanic corrosion on the hull.
Safe shore power: Protects both systems and people in case of faults in the harbor grid.
Robust construction: Built for permanent operation in a humid environment.
Application
Shore power in boats where galvanic corrosion must be avoided.
Adaptation between different grid voltages.
Safe isolation of ship and harbor grid.
Specifications
Specification
Details
Weight
28 kg
Dimensions (h × w × d)
243 × 258 × 362 mm
Part number
ITR000802002
Download datasheet (PDF)
Victron Isolation transformer 7000W 230V – galvanic isolation of shore powerThe Victron Isolation transformer 7000W 230V from Victron Energy provides galvanic isolation between shore power and the onboard installation. It stops galvanic corrosion on the hull and makes the shore connection safe.Advantages
Galvanic isolation: Breaks the connection to the harbor's earth and stops galvanic corrosion on the hull.
Safe shore power: Protects both the system and personnel in case of faults in the harbor grid.
Robust construction: Built for permanent operation in a humid environment.
Application
Shore power in boats where galvanic corrosion must be avoided.
Adjustment between different mains voltages.
Safe isolation of the vessel and the harbor grid.
Specifications
Specification
Details
Nominal voltage
6/12/24 V
Weight
30 kg
Dimensions (h × w × d)
218 × 258 × 362 mm
Item number
ITR000702001
Download datasheet (PDF)
Victron Isolation transformer 2500W 115/230V – galvanic isolation of shore powerThe Victron Isolation transformer 2500W 115/230V from Victron Energy provides galvanic isolation between shore power and the onboard installation. It stops galvanic corrosion on the hull and makes the shore connection safe.Advantages
Galvanic isolation: Breaks the connection to the harbor ground and stops galvanic corrosion on the hull.
Safe shore power: Protects both the system and people in the event of a fault in the harbor grid.
Robust construction: Built for permanent operation in a humid environment.
Application
Shore power in a boat where galvanic corrosion must be avoided.
Adaptation between different grid voltages.
Safe separation of the ship and the harbor grid.
Specifications
Specification
Details
AC input voltage
115 or 230 V
AC output
120 or 240 V
Frequency
50/60 Hz
Output current rating
17 A (115 V) / 8.5 A (230 V)
Soft start
Yes
Operating temperature range
-20 °C to 40 °C
Humidity
max. 95%, non-condensing
Transformer type
Toroidal (low noise, low weight), 1:1.05 ratio
Enclosure
aluminium (blue RAL 5012)
Protection class
IP21
Safety
EN 60076
Weight
12.7 kg
Dimensions (h × w × d)
375 × 214 × 135
Item number
ITR040252043
Download datasheet (PDF)
Victron Isolation transformer 2000W 115/230V – galvanic isolation of shore powerThe Victron Isolation transformer 2000W 115/230V from Victron Energy provides galvanic isolation between shore power and the onboard installation. It stops galvanic corrosion on the hull and makes the shore connection safe.Benefits
Galvanic isolation: Breaks the connection to the shore ground and stops galvanic corrosion on the hull.
Safe shore power: Protects both the system and people in the event of faults in the shore grid.
Robust construction: Built for permanent operation in a humid environment.
Application
Shore power in boats where galvanic corrosion must be avoided.
Matching between different mains voltages.
Safe isolation of the vessel from the shore grid.
Specifications
Specification
Details
AC input voltage
115 or 230 V
AC output
120 or 240 V
Frequency
50/60 Hz
Output current rating
17 A (115 V) / 8.5 A (230 V)
Soft start
Yes
Operating temperature range
-20 °C to 40 °C
Humidity
max. 95%, non-condensing
Transformer type
Toroidal (low noise, low weight), 1:1.05 ratio
Enclosure
aluminium (blue RAL 5012)
Protection class
IP21
Safety
EN 60076
Weight
12.7 kg
Dimensions (h × w × d)
375 × 214 × 135
Rated voltage
6/12/24 V
Item number
ITR040202041
Download datasheet (PDF)
Victron Isolation transformer 4500W Auto 115/230 – galvanic isolation of shore powerThe Victron Isolation transformer 4500W Auto 115/230 from Victron Energy provides galvanic isolation between shore power and the onboard installation. It stops galvanic corrosion on the hull and makes the shore connection safe.Advantages
Galvanic isolation: Breaks the connection to the harbor's ground and stops galvanic corrosion on the hull.
Safe shore power: Protects both systems and people in the event of faults in the harbor grid.
Robust construction: Built for continuous operation in a humid environment.
Application
Shore power in a boat where galvanic corrosion must be avoided.
Adaptation between different mains voltages.
Safe separation of the vessel and the harbor grid.
Specifications
Specification
Details
AC input voltage
115 or 230 V, automatic detection
AC output
120 or 240 V
Frequency
50/60 Hz
Output current rating
38 A (115 V) / 19 A (230 V)
Soft start
Yes
Operating temperature range
-20 °C to 40 °C
Humidity
max. 95%, non-condensing
Transformer type
Toroidal (low noise, low weight), 1:1.05 ratio
Enclosure
aluminum (blue RAL 5012)
Protection class
IP21
Safety
EN 60076
Weight
21.8 kg
Dimensions (h × w × d)
362 × 258 × 221
Item number
ITR050452042
Download datasheet (PDF)
Victron Isolation transformer 3600W 115/230V – galvanic isolation from shore powerThe Victron Isolation transformer 3600W 115/230V from Victron Energy provides galvanic isolation between shore power and the onboard installation. It stops galvanic corrosion on the hull and makes the shore connection safe.Advantages
Galvanic isolation: Breaks the connection to the harbor's ground and stops galvanic corrosion on the hull.
Safe shore power: Protects both systems and people in the event of faults in the harbor's power grid.
Robust construction: Built for permanent operation in a humid environment.
Application
Shore power in a boat where galvanic corrosion must be avoided.
Adjustment between different mains voltages.
Safe separation of vessel and harbor power grid.
Specifications
Specification
Details
AC input voltage
115 or 230 V
AC output
120 or 240 V
Frequency
50/60 Hz
Output current rating
17 A (115 V) / 8.5 A (230 V)
Soft start
Yes
Operating temperature range
-20 °C to 40 °C
Humidity
max. 95%, non-condensing
Transformer type
Toroidal (low noise, low weight), 1:1.05 ratio
Enclosure
aluminum (blue RAL 5012)
Protection class
IP21
Safety
EN 60076
Weight
12.7 kg
Dimensions (h × w × d)
375 × 214 × 135
Nominal voltage
6/12/24 V
Item number
ITR040362041
Download datasheet (PDF)
Victron Autotransformer 120/240 VAC-32A – galvanic isolation of shore powerThe Victron Autotransformer 120/240 VAC-32A from Victron Energy provides galvanic isolation between shore power and the onboard installation. It stops galvanic corrosion on the hull and makes the shore connection safe.Advantages
Galvanic isolation: Breaks the connection to the harbor ground and stops galvanic corrosion on the hull.
Safe shore power: Protects both the system and personnel in case of faults in the harbor grid.
Robust construction: Built for continuous operation in a humid environment.
Application
Shore power in boats where galvanic corrosion must be avoided.
Matching different grid voltages.
Safe isolation of the vessel and the harbor grid.
Specifications
Specification
Details
Input/output voltage
120 / 240 V
Input Circuit Breaker
50 A, Two Pole
Frequency
50/60 Hz
Max. 240 V Feed Through current
50 A
Neutral current, 30 min.
55 A @ 40 °C/100°F
Neutral current, Continuous
45 A @ 40 °C/100°F
Transformer type
Toroidal
Enclosure
Aluminum
Electrical terminals
screw terminals 35 mm² / AWG
Protection class
IP21
Safety
EN 60076
Weight
12.5 kg
Dimensions (h × w × d)
460 × 214 × 110 mm
Nominal voltage
6/12/24 V
Item number
ITR000100001
Download datasheet (PDF)
Victron Autotransformer 120/240 VAC-50A – galvanic isolation of shore powerThe Victron Autotransformer 120/240 VAC-50A from Victron Energy provides galvanic isolation between shore power and the onboard installation. It stops galvanic corrosion on the hull and makes the shore connection safe.Benefits
Galvanic isolation: Breaks the connection to the harbor's ground and stops galvanic corrosion on the hull.
Safe shore power: Protects both the system and people in the event of faults in the harbor grid.
Robust construction: Built for permanent operation in a humid environment.
Application
Shore power in boats where galvanic corrosion must be avoided.
Adaptation between different grid voltages.
Safe isolation of the vessel and the harbor grid.
Specifications
Specification
Details
Input/output voltage
120 / 240 V
Input Circuit Breaker
50 A, Two Pole
Frequency
50/60 Hz
Max. 240 V Feed Through current
50 A
Neutral current, 30 min.
55 A @ 40 °C/100°F
Neutral current, Continuous
45 A @ 40 °C/100°F
Transformer type
Toroidal
Enclosure
Aluminum
Electrical terminals
screw terminals 35 mm² / AWG
Protection class
IP21
Safety
EN 60076
Weight
12.5 kg
Dimensions (h × w × d)
460 × 214 × 110 mm
EAN
8719076066071
Item number
ITR000100052
Download datasheet (PDF)
Victron Autotransformer 120/240 VAC-100A – galvanic isolation of shore powerThe Victron Autotransformer 120/240 VAC-100A from Victron Energy provides galvanic isolation between shore power and the onboard installation. It prevents galvanic corrosion on the hull and makes the shore connection safe.Advantages
Galvanic isolation: Breaks the connection to the harbor's ground and stops galvanic corrosion on the hull.
Safe shore power: Protects both systems and personnel in the event of faults in the harbor grid.
Robust construction: Built for permanent operation in a humid environment.
Applications
Shore power in boats where galvanic corrosion must be avoided.
Matching between different grid voltages.
Safe isolation of the vessel from the harbor grid.
Specifications
Specification
Details
Input/output voltage
120 / 240 V
Input Circuit Breaker
50 A, Two Pole
Frequency
50/60 Hz
Max. 240 V Feed Through current
50 A
Neutral current, 30 min.
55 A @ 40 °C/100°F
Neutral current, Continuous
45 A @ 40 °C/100°F
Transformer type
Toroidal
Enclosure
Aluminum
Electrical terminals
screw terminals 35 mm² / AWG
Protection class
IP21
Safety
EN 60076
Weight
12.5 kg
Dimensions (h × w × d)
460 × 214 × 110 mm
Nominal voltage
6/12/24 V
Part number
ITR000100101
Download datasheet (PDF)
Isolation transformers galvanically isolate the boat from the shore power ground and prevent corrosion currents in the hull. Standard equipment in marine installations with a permanent shore power connection.