Victron Isolation Transformers

Best price on Victron in Denmark 704 Victron products · Prices checked monthly · Price match
11 products

  • Victron Isolations transformer 4500W 115/230V

    Victron Victron Isolation Transformer 4500W 115/230V

    2-4 day delivery

    Victron Isolation transformer 4500W 115/230V – galvanic isolation of shore powerThe Victron Isolation transformer 4500W 115/230V from Victron Energy provides galvanic isolation between shore power and the onboard installation. It stops galvanic corrosion on the hull and makes the shore connection safe.Advantages Galvanic isolation: Breaks the connection to the harbor ground and stops galvanic corrosion on the hull. Safe shore power: Protects both the installation and people in case of faults in the harbor grid. Robust construction: Built for permanent operation in a humid environment. Application Shore power in boats, where galvanic corrosion must be avoided. Adjustment between different grid voltages. Safe separation of the vessel and the harbor grid. Specifications Specification Details AC input voltage 115 or 230 V AC output 120 or 240 V Frequency 50/60 Hz Output current rating 17 A (115 V) / 8.5 A (230 V) Soft start Yes Operating temperature range -20 °C to 40 °C Humidity max. 95%, non-condensing Transformer type Toroidal (low noise, low weight), 1:1.05 ratio Enclosure aluminium (blue RAL 5012) Protection class IP21 Safety EN 60076 Weight 12.7 kg Dimensions (h × w × d) 375 × 214 × 135 Item number ITR040452042 Download datasheet (PDF)

    2-4 day delivery

    4.889,00 kr

  • Victron Isolations transformer 3600W 115/230V

    Victron Victron Isolation Transformer 3600W 115/230V (ITR040362042)

    2-4 day delivery

    Victron Isolation Transformer 3600W 115/230V – galvanic isolation of shore powerThe Victron Isolation Transformer 3600W 115/230V from Victron Energy provides galvanic isolation between shore power and the onboard installation. It stops galvanic corrosion on the hull and makes the shore connection safe.Advantages Galvanic isolation: Breaks the connection to the harbor's ground and stops galvanic corrosion on the hull. Safe shore power: Protects both the system and personnel in case of faults in the harbor's grid. Robust construction: Built for continuous operation in a humid environment. Application Shore power in boats where galvanic corrosion must be avoided. Adjustment between different grid voltages. Safe separation of the vessel and the harbor grid. Specifications Specification Details AC input voltage 115 or 230 V AC output 120 or 240 V Frequency 50/60 Hz Output current rating 17 A (115 V) / 8.5 A (230 V) Soft start Yes Operating temperature range -20 °C to 40 °C Humidity max. 95%, non-condensing Transformer type Toroidal (low noise, low weight), 1:1.05 ratio Enclosure aluminum (blue RAL 5012) Protection class IP21 Safety EN 60076 Weight 12.7 kg Dimensions (h × w × d) 375 × 214 × 135 Part number ITR040362042 Download datasheet (PDF)

    2-4 day delivery

    4.179,00 kr

  • Victron isolations transformer 8000W 230V

    Victron Victron Isolation Transformer 8000W 230V

    2-4 day delivery

    Victron Isolation transformer 8000W 230V – galvanic isolation of shore powerThe Victron Isolation transformer 8000W 230V from Victron Energy provides galvanic isolation between shore power and the onboard installation. It stops galvanic corrosion on the hull and makes the shore connection safe.Advantages Galvanic isolation: Breaks the connection to the harbor ground and stops galvanic corrosion on the hull. Safe shore power: Protects both systems and people in case of faults in the harbor grid. Robust construction: Built for permanent operation in a humid environment. Application Shore power in boats where galvanic corrosion must be avoided. Adaptation between different grid voltages. Safe isolation of ship and harbor grid. Specifications Specification Details Weight 28 kg Dimensions (h × w × d) 243 × 258 × 362 mm Part number ITR000802002 Download datasheet (PDF)

    2-4 day delivery

    6.289,00 kr

  • Save 19 % Victron isolations transformer 7000W 230V

    Victron Victron Isolation Transformer 7000W 230V

    2-4 day delivery

    Victron Isolation transformer 7000W 230V – galvanic isolation of shore powerThe Victron Isolation transformer 7000W 230V from Victron Energy provides galvanic isolation between shore power and the onboard installation. It stops galvanic corrosion on the hull and makes the shore connection safe.Advantages Galvanic isolation: Breaks the connection to the harbor's earth and stops galvanic corrosion on the hull. Safe shore power: Protects both the system and personnel in case of faults in the harbor grid. Robust construction: Built for permanent operation in a humid environment. Application Shore power in boats where galvanic corrosion must be avoided. Adjustment between different mains voltages. Safe isolation of the vessel and the harbor grid. Specifications Specification Details Nominal voltage 6/12/24 V Weight 30 kg Dimensions (h × w × d) 218 × 258 × 362 mm Item number ITR000702001 Download datasheet (PDF)

    2-4 day delivery

    Other retailers8.220,00 kr 6.629,00 kr

  • Victron Isolations transformer 2500W 115/230V

    Victron Victron Isolation Transformer 2500W 115/230V

    2-4 day delivery

    Victron Isolation transformer 2500W 115/230V – galvanic isolation of shore powerThe Victron Isolation transformer 2500W 115/230V from Victron Energy provides galvanic isolation between shore power and the onboard installation. It stops galvanic corrosion on the hull and makes the shore connection safe.Advantages Galvanic isolation: Breaks the connection to the harbor ground and stops galvanic corrosion on the hull. Safe shore power: Protects both the system and people in the event of a fault in the harbor grid. Robust construction: Built for permanent operation in a humid environment. Application Shore power in a boat where galvanic corrosion must be avoided. Adaptation between different grid voltages. Safe separation of the ship and the harbor grid. Specifications Specification Details AC input voltage 115 or 230 V AC output 120 or 240 V Frequency 50/60 Hz Output current rating 17 A (115 V) / 8.5 A (230 V) Soft start Yes Operating temperature range -20 °C to 40 °C Humidity max. 95%, non-condensing Transformer type Toroidal (low noise, low weight), 1:1.05 ratio Enclosure aluminium (blue RAL 5012) Protection class IP21 Safety EN 60076 Weight 12.7 kg Dimensions (h × w × d) 375 × 214 × 135 Item number ITR040252043 Download datasheet (PDF)

    2-4 day delivery

    3.599,00 kr

  • Save 4 % Victron isolations transformer 2000W 115/230V

    Victron Victron Isolation Transformer 2000W 115/230V

    2-4 day delivery

    Victron Isolation transformer 2000W 115/230V – galvanic isolation of shore powerThe Victron Isolation transformer 2000W 115/230V from Victron Energy provides galvanic isolation between shore power and the onboard installation. It stops galvanic corrosion on the hull and makes the shore connection safe.Benefits Galvanic isolation: Breaks the connection to the shore ground and stops galvanic corrosion on the hull. Safe shore power: Protects both the system and people in the event of faults in the shore grid. Robust construction: Built for permanent operation in a humid environment. Application Shore power in boats where galvanic corrosion must be avoided. Matching between different mains voltages. Safe isolation of the vessel from the shore grid. Specifications Specification Details AC input voltage 115 or 230 V AC output 120 or 240 V Frequency 50/60 Hz Output current rating 17 A (115 V) / 8.5 A (230 V) Soft start Yes Operating temperature range -20 °C to 40 °C Humidity max. 95%, non-condensing Transformer type Toroidal (low noise, low weight), 1:1.05 ratio Enclosure aluminium (blue RAL 5012) Protection class IP21 Safety EN 60076 Weight 12.7 kg Dimensions (h × w × d) 375 × 214 × 135 Rated voltage 6/12/24 V Item number ITR040202041 Download datasheet (PDF)

    2-4 day delivery

    Other retailers3.456,00 kr 3.309,00 kr

  • Victron isolations transformer 4500W Auto 115/230

    Victron Victron Isolation Transformer 4500W Auto 115/230V

    2-4 day delivery

    Victron Isolation transformer 4500W Auto 115/230 – galvanic isolation of shore powerThe Victron Isolation transformer 4500W Auto 115/230 from Victron Energy provides galvanic isolation between shore power and the onboard installation. It stops galvanic corrosion on the hull and makes the shore connection safe.Advantages Galvanic isolation: Breaks the connection to the harbor's ground and stops galvanic corrosion on the hull. Safe shore power: Protects both systems and people in the event of faults in the harbor grid. Robust construction: Built for continuous operation in a humid environment. Application Shore power in a boat where galvanic corrosion must be avoided. Adaptation between different mains voltages. Safe separation of the vessel and the harbor grid. Specifications Specification Details AC input voltage 115 or 230 V, automatic detection AC output 120 or 240 V Frequency 50/60 Hz Output current rating 38 A (115 V) / 19 A (230 V) Soft start Yes Operating temperature range -20 °C to 40 °C Humidity max. 95%, non-condensing Transformer type Toroidal (low noise, low weight), 1:1.05 ratio Enclosure aluminum (blue RAL 5012) Protection class IP21 Safety EN 60076 Weight 21.8 kg Dimensions (h × w × d) 362 × 258 × 221 Item number ITR050452042 Download datasheet (PDF)

    2-4 day delivery

    4.389,00 kr

  • Victron isolations transformer 3600W 115/230V

    Victron Victron Isolation Transformer 3600W 115/230V (ITR040362041)

    2-4 day delivery

    Victron Isolation transformer 3600W 115/230V – galvanic isolation from shore powerThe Victron Isolation transformer 3600W 115/230V from Victron Energy provides galvanic isolation between shore power and the onboard installation. It stops galvanic corrosion on the hull and makes the shore connection safe.Advantages Galvanic isolation: Breaks the connection to the harbor's ground and stops galvanic corrosion on the hull. Safe shore power: Protects both systems and people in the event of faults in the harbor's power grid. Robust construction: Built for permanent operation in a humid environment. Application Shore power in a boat where galvanic corrosion must be avoided. Adjustment between different mains voltages. Safe separation of vessel and harbor power grid. Specifications Specification Details AC input voltage 115 or 230 V AC output 120 or 240 V Frequency 50/60 Hz Output current rating 17 A (115 V) / 8.5 A (230 V) Soft start Yes Operating temperature range -20 °C to 40 °C Humidity max. 95%, non-condensing Transformer type Toroidal (low noise, low weight), 1:1.05 ratio Enclosure aluminum (blue RAL 5012) Protection class IP21 Safety EN 60076 Weight 12.7 kg Dimensions (h × w × d) 375 × 214 × 135 Nominal voltage 6/12/24 V Item number ITR040362041 Download datasheet (PDF)

    2-4 day delivery

    5.589,00 kr

  • Save 14 % Victron autotransformer 120/240VAC-32A

    Victron Victron Autotransformer 120/240 VAC-32A

    2-4 day delivery

    Victron Autotransformer 120/240 VAC-32A – galvanic isolation of shore powerThe Victron Autotransformer 120/240 VAC-32A from Victron Energy provides galvanic isolation between shore power and the onboard installation. It stops galvanic corrosion on the hull and makes the shore connection safe.Advantages Galvanic isolation: Breaks the connection to the harbor ground and stops galvanic corrosion on the hull. Safe shore power: Protects both the system and personnel in case of faults in the harbor grid. Robust construction: Built for continuous operation in a humid environment. Application Shore power in boats where galvanic corrosion must be avoided. Matching different grid voltages. Safe isolation of the vessel and the harbor grid. Specifications Specification Details Input/output voltage 120 / 240 V Input Circuit Breaker 50 A, Two Pole Frequency 50/60 Hz Max. 240 V Feed Through current 50 A Neutral current, 30 min. 55 A @ 40 °C/100°F Neutral current, Continuous 45 A @ 40 °C/100°F Transformer type Toroidal Enclosure Aluminum Electrical terminals screw terminals 35 mm² / AWG Protection class IP21 Safety EN 60076 Weight 12.5 kg Dimensions (h × w × d) 460 × 214 × 110 mm Nominal voltage 6/12/24 V Item number ITR000100001 Download datasheet (PDF)

    2-4 day delivery

    Other retailers4.540,00 kr 3.889,00 kr

  • Victron Autotransformer 120/240 VAC-50A

    Victron Victron Autotransformer 120/240 VAC-50A

    2-4 day delivery

    Victron Autotransformer 120/240 VAC-50A – galvanic isolation of shore powerThe Victron Autotransformer 120/240 VAC-50A from Victron Energy provides galvanic isolation between shore power and the onboard installation. It stops galvanic corrosion on the hull and makes the shore connection safe.Benefits Galvanic isolation: Breaks the connection to the harbor's ground and stops galvanic corrosion on the hull. Safe shore power: Protects both the system and people in the event of faults in the harbor grid. Robust construction: Built for permanent operation in a humid environment. Application Shore power in boats where galvanic corrosion must be avoided. Adaptation between different grid voltages. Safe isolation of the vessel and the harbor grid. Specifications Specification Details Input/output voltage 120 / 240 V Input Circuit Breaker 50 A, Two Pole Frequency 50/60 Hz Max. 240 V Feed Through current 50 A Neutral current, 30 min. 55 A @ 40 °C/100°F Neutral current, Continuous 45 A @ 40 °C/100°F Transformer type Toroidal Enclosure Aluminum Electrical terminals screw terminals 35 mm² / AWG Protection class IP21 Safety EN 60076 Weight 12.5 kg Dimensions (h × w × d) 460 × 214 × 110 mm EAN 8719076066071 Item number ITR000100052 Download datasheet (PDF)

    2-4 day delivery

    4.339,00 kr

  • Victron Autotransformer 120/240 VAC-100A

    Victron Victron Autotransformer 120/240 VAC-100A

    2-4 day delivery

    Victron Autotransformer 120/240 VAC-100A – galvanic isolation of shore powerThe Victron Autotransformer 120/240 VAC-100A from Victron Energy provides galvanic isolation between shore power and the onboard installation. It prevents galvanic corrosion on the hull and makes the shore connection safe.Advantages Galvanic isolation: Breaks the connection to the harbor's ground and stops galvanic corrosion on the hull. Safe shore power: Protects both systems and personnel in the event of faults in the harbor grid. Robust construction: Built for permanent operation in a humid environment. Applications Shore power in boats where galvanic corrosion must be avoided. Matching between different grid voltages. Safe isolation of the vessel from the harbor grid. Specifications Specification Details Input/output voltage 120 / 240 V Input Circuit Breaker 50 A, Two Pole Frequency 50/60 Hz Max. 240 V Feed Through current 50 A Neutral current, 30 min. 55 A @ 40 °C/100°F Neutral current, Continuous 45 A @ 40 °C/100°F Transformer type Toroidal Enclosure Aluminum Electrical terminals screw terminals 35 mm² / AWG Protection class IP21 Safety EN 60076 Weight 12.5 kg Dimensions (h × w × d) 460 × 214 × 110 mm Nominal voltage 6/12/24 V Part number ITR000100101 Download datasheet (PDF)

    2-4 day delivery

    4.179,00 kr

Isolation transformers galvanically isolate the boat from the shore power ground and prevent corrosion currents in the hull. Standard equipment in marine installations with a permanent shore power connection.

Login

Forgot your password?

Don't have an account yet?
Create account