Victron Galvanic Isolator VDI-64 A – galvanic isolation of shore powerThe Victron Galvanic Isolator VDI-64 A from Victron Energy provides galvanic isolation between shore power and the onboard installation. It stops galvanic corrosion of the hull and makes the shore connection safe.Advantages
Galvanic isolation: Breaks the connection to the shore ground and stops galvanic corrosion of the hull.
Safe shore power: Protects both systems and persons in case of faults in the shore grid.
Robust construction: Built for permanent operation in a humid environment.
Application
Shore power in boats where galvanic corrosion must be avoided.
Adaptation between different grid voltages.
Safe isolation of the vessel and the shore grid.
Specifications
Specification
Details
Nominal voltage
6/12/24 V
Weight
2 kg
Dimensions (h × w × d)
224 × 164 × 64 mm
Item number
GDI000064000
Download datasheet (PDF)
Victron Galvanic Isolator VDI-32 A – galvanic isolation of shore powerThe Victron Galvanic Isolator VDI-32 A from Victron Energy provides galvanic isolation between shore power and the onboard installation. It stops galvanic corrosion on the hull and makes the shore connection safe.Advantages
Galvanic isolation: Breaks the connection to the marina's earth and stops galvanic corrosion on the hull.
Safe shore power: Protects both systems and personnel in case of faults in the marina's grid.
Robust construction: Built for permanent operation in a humid environment.
Application
Shore power in boats where galvanic corrosion must be avoided.
Adaptation between different grid voltages.
Safe separation of vessel and the marina's grid.
Specifications
Specification
Details
Nominal voltage
6/12/24 V
Weight
2.1 kg
Dimensions (h × w × d)
235 × 164 × 63 mm
Item number
GDI000032000
Download datasheet (PDF)
Victron Galvanic Isolator VDI-16 A – galvanic isolation of shore powerThe Victron Galvanic Isolator VDI-16 A from Victron Energy provides galvanic isolation between shore power and the onboard installation. It stops galvanic corrosion on the hull and makes the shore connection safe.Advantages
Galvanic isolation: Breaks the connection to the harbor's ground and stops galvanic corrosion on the hull.
Safe shore power: Protects both the system and people in the event of faults in the harbor's power grid.
Robust construction: Built for continuous operation in a humid environment.
Application
Shore power in boats where galvanic corrosion must be avoided.
Matching between different mains voltages.
Safe separation of the vessel and the harbor's power grid.
Specifications
Specification
Details
Rated voltage
6/12/24 V
Weight
1.6 kg
Dimensions (h × w × d)
200 × 120 × 60 mm
Part number
GDI000016000
Download datasheet (PDF)
Galvanic isolators are a simpler and less expensive solution than an isolation transformer and block galvanic currents in the grounding connection. Choose according to the shore power amperage.