| Battery type |
Lithium-ion |
| Battery voltage range |
160-800 V |
| Max. charge current |
50+50 A |
| Max. discharge current |
50+50 A |
| Charging strategy for lithium battery |
Automatic adaptation to BMS |
| Number of battery inputs |
2 |
| Max. connected PV power |
100,000 W |
| Max. DC input power |
80,000 W |
| Max. DC input voltage |
1,000 V |
| Start-up voltage |
180 V |
| MPPT voltage range |
150-850 V |
| Nominal DC input voltage |
600 V |
| Max. short-circuit current, input |
55+55+55+55 A |
| Max. PV operating current |
36+36+36+36 A |
| Number of MPPT / strings per MPPT |
4/2+2+2+2 |
| Nominal AC input/output power |
50,000 W |
| Max. AC input/output power (VA) |
55,000 VA |
| Peak power (off-grid) |
1.5 × nominal power for 10 s |
| Nominal AC input/output current |
75.8/72.5 A |
| Max. AC input/output current |
83.4/79.8 A |
| Max. continuous AC pass-through (grid to load) |
200 A |
| Nominal input/output voltage |
220/380V, 230/400V 0.85Un-1.1Un |
| Grid connection |
3L+N+PE |
| Nominal grid frequency / range |
50/45-55, 60/55-65 |
| Power factor, adjustment range |
0.8 leading – 0.8 lagging |
| Harmonic current distortion (THDi) |
<3% (of nominal power) |
| DC injection current |
<0.5 %ln |
| Max. efficiency |
97.60% |
| Euro efficiency |
97.0% |
| MPPT efficiency |
>99% |
| Built-in protection |
Reverse DC polarity protection, AC output overcurrent protection, thermal protection, AC output overvoltage protection, AC output short-circuit protection, DC component monitoring, arc fault detection (AFCI) (optional), anti-islanding protection, DC switch, insulation monitoring, residual current monitoring |
| Surge protection |
Type II(DC), Type II(AC) |
| Communication interface |
RS485/RS232/CAN |
| Monitoring |
GPRS/WiFi/Bluetooth/4G/LAN (optional) |
| Operating temperature |
-40°C+60°C, >45°C derating |
| Permissible humidity |
0-100% |
| Max. installation altitude |
2,000m |
| Noise level |
≤ 65 dB(A) |
| Ingress protection (IP) |
IP65 |
| Inverter topology |
Non-isolated |
| Overvoltage category |
OVC II(DC), OVC III(AC) |
| Dimensions (W×H×D) |
527*894*294 (excl. connectors and brackets) |
| Weight |
80 kg |
| Warranty |
5 years / 10 years (warranty period depends on the inverter's installation location – see Deye's warranty policy) |
| Cooling |
Intelligent air cooling |
| Grid standards |
IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105 |
| Safety / EMC standards |
IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |