| Battery type |
Lead-acid or lithium-ion |
| Battery voltage range |
40-60 V |
| Max. charge/discharge current |
280 A |
| Charging strategy for lithium battery |
Automatic adaptation to BMS |
| Number of battery inputs |
2 |
| Max. connected PV power |
30,000 W |
| Max. PV input power |
24,000 W |
| Max. PV input voltage |
800 V |
| Start-up voltage |
160 V |
| MPPT voltage range |
160-650 V |
| Rated PV input voltage |
550 V |
| Max. PV operating current |
36+36 A |
| Max. short-circuit current, input |
54+54 A |
| Number of MPPTs / strings per MPPT |
2/2+2 |
| Rated AC input/output power |
15,000 W |
| Max. AC input/output power (VA) |
16,500 VA |
| Rated AC input/output current |
22.8/21.8 A |
| Max. AC input/output current |
25/24 A |
| Max. continuous AC pass-through (grid to load) |
70 A |
| Peak power (off-grid mode) |
2 × rated power for 10 s |
| Power factor, adjustment range |
0.8 leading to 0.8 lagging |
| Rated input/output voltage |
220/380V, 230/400V 0.85Un-1.1Un 3L+N+PE |
| Rated grid frequency / range |
50/45-55, 60/55-65 Hz |
| Total harmonic current distortion (THDi) |
<3 % (of rated power) |
| DC injection into grid |
<0.5 % In |
| Max. efficiency |
97,6 % |
| Euro efficiency |
97,0 % |
| MPPT efficiency |
>99 % |
| Built-in protection |
DC reverse polarity protection, AC output overcurrent protection, thermal protection, AC output overvoltage protection, AC output short-circuit protection, DC component monitoring, load overvoltage protection, earth fault monitoring, arc fault detection (AFCI) (optional), grid monitoring, islanding monitoring, earth fault detection, DC input switch, insulation monitoring on DC terminals, residual current detection (RCD), surge protection |
| Surge protection |
Type II(DC), Type II(AC) |
| Display |
LCD display |
| Communication interface |
WiFi, RS485, CAN |
| Operating temperature |
-40 to +60°C, >45°C derating |
| Permitted humidity |
0-100 % |
| Max. installation altitude |
3,000m |
| Noise level |
<60 dB |
| Protection rating (IP) |
IP65 |
| Inverter topology |
Non-isolated (PV), isolated (battery) |
| Overvoltage category |
OVC II(DC), OVC III(AC) |
| Dimensions (W×H×D) |
456×750×268.5 (excl. connectors and bracket) |
| Weight |
51.9 kg |
| Cooling |
Intelligent air cooling |
| Warranty |
5 years / 10 years (the warranty period depends on where the inverter is installed – see Deye's warranty policy) |
| Grid standards |
IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105 |
| Safety / EMC standards |
IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |