| Specification |
Details |
| PowerControl and PowerAssist |
Yes |
| Automatic transfer switch |
50 A |
| Max. AC input and pass-through current |
50 A |
| DC input voltage range |
38 – 62 V |
| AC output |
output voltage: 230 Vac ± 2 % / Frequency: 50 Hz ± 0.1 % (1) / Maximum continuous inverter current: 25 Aac |
| Continuous output power at 25 °C |
Increases linearly from 4600 W at 46 VDC to 5200 W at 52 VDC |
| Continuous output power at 40 °C |
4500 W |
| Continuous output power at 65 °C |
3000 W |
| Peak power |
9 kW for 3 seconds / 7 kW for 4 minutes |
| Short-circuit current on output |
45 A |
| Max. AC output overcurrent protection |
30 A |
| Max. efficiency |
96.5 % at 1 kW consumption / 94 % at 5 kW consumption |
| Zero-load consumption |
20 W |
| Low battery voltage disconnect |
37.2 V (adjustable) |
| Low battery restart |
43.6 V (adjustable) |
| Max. DC voltage |
450 V |
| Start-up voltage |
120 V |
| MPPT voltage range |
65 – 450 V |
| Max. operational PV input current limit |
12 A |
| Max. PV short-circuit current |
16 A |
| Max. DC solar charging power |
6000 W total - 3000 W per tracker |
| Earth leakage trip level |
30 mA |
| Isolation fail level (detection before start-up) |
100 kΩ |
| AC input |
input voltage range: 187-265 VAC / input frequency: 45-65 Hz / Nominal voltage 230 Vac / Nominal frequency: 50 Hz / AC inrush current: NA |
| Icw and Ipk requirements |
Icw: 500 A @ 0.1s and Ipk: 2kA |
| Programmable charger voltage range |
36 - 60 V |
| Absorption charge voltage |
default: 57.6 V (adjustable) |
| Float charge voltage |
default: 55.2 V (adjustable) |
| Max. charge current from AC |
88 A @ 57.6 V |
| Total max. combined charger current (AC + PV) |
100 A |
| Battery temperature sensor |
included |
| Battery voltage sensing |
Yes |
| Parallel and 3-phase operation |
3 Phase supports 1 unit per phase. Parallel is not supported. |
| Auxiliary output |
Yes |
| Programmable relay |
Yes |
| Protection |
a - g |
| Data Communications |
VE.Direct port, VE.Can port & Bluetooth |
| Bluetooth frequency |
2402 - 2480 MHz |
| Bluetooth power |
4 dBm |
| General purpose analog/digital in port |
Yes, 2x |
| Remote on/off |
Yes |
| Operating temperature range |
-40 to +65 °C (fan cooled) |
| Max. altitude |
2000 m |
| Humidity (non-condensing) |
max. 95 % |
| Earthing system |
TN, TT only |
| Material |
steel, blue RAL 5012 |
| Enclosure class |
IP21 / Protective Class: I |
| Battery connection |
M8 Bolts |
| PV connection |
2 strings, each with positive and negative MC4 |
| 230 V AC connection |
screw terminals 10 mm² (6 AWG) |
| Weight |
12.3 kg |
| Dimensions (h × w × d) |
462 × 425 × 127 mm |
| Safety |
EN-IEC 60335-1, EN-IEC 60335-2-29, EN-IEC 62109-1, EN-IEC 62109-2 / IEC 62040, IEC 62477 |
| Emission / immunity |
EN 55014-1, EN 55014-2 EN-IEC 61000-3-2, EN-IEC 61000-3-3 / IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3 / Pollution Degree |
| Overvoltage category |
battery: OVC I / PV port: OVC II / AC in / AC out: OVC III |
| UPS Specification |
input: 230VAC, 46 A, 50 Hz / output: 230VAC, 26 A, 50 Hz, 6 kVA / 5 kW / Protective device (input and output): max. 50 A circuit breaker |
| Nominal voltage |
48 V |
| Item number |
PMR482602020 |