{"product_id":"deye-sun-6k-sg05lp1-hybrid-inverter-1-faset","title":"Deye SUN-6K-SG05LP1-EU-AM2-P hybrid inverter 6 kW 1-phase","description":"\u003ch2\u003eDeye SUN-6K-SG05LP1-EU-AM2-P hybrid inverter 6 kW 1-phase – solar inverter, battery charger and emergency power supply in one unit.\u003c\/h2\u003e\u003cp\u003eThe Deye SUN-6K-SG05LP1-EU-AM2-P is a 6 kW 1-phase hybrid inverter that combines a solar inverter, battery charger, and emergency power supply into one unit. With 2 MPPT trackers and up to 12,000 W of connected solar power, it can both work in tandem with the grid and provide backup power to the house if the electricity goes out. This means you can store your own solar energy in the battery and use it when you actually need it – instead of selling it cheaply to the grid.\u003c\/p\u003e\u003ch3\u003eBenefits\u003c\/h3\u003e\u003cul\u003e\n\n\u003cli\u003eRated power 6,000 W\u003c\/li\u003e\n\n\u003cli\u003e2 independent MPPT trackers for flexible string configuration\u003c\/li\u003e\n\n\u003cli\u003eUp to 12,000 W solar power capacity can be connected\u003c\/li\u003e\n\n\u003cli\u003eMax. charge\/discharge current 135 A to battery\u003c\/li\u003e\n\n\u003cli\u003ePeak power in off-grid operation: 2 × rated power for 10 s\u003c\/li\u003e\n\n\u003cli\u003eEfficiency up to 97.6%\u003c\/li\u003e\n\n\u003cli\u003eProtection class IP65 – suitable for outdoor installation\u003c\/li\u003e\n\n\u003cli\u003eBuilt-in LCD display for local operation and monitoring\u003c\/li\u003e\n\n\u003cli\u003eCommunication via WiFi, RS485, CAN\u003c\/li\u003e\n\n\u003cli\u003eReady for remote monitoring via Deye Cloud \/ SOLARMAN (requires data logger)\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003ch3\u003eApplication\u003c\/h3\u003e\u003cul\u003e\n\n\u003cli\u003eSolar power systems with battery storage for private homes and small businesses\u003c\/li\u003e\n\n\u003cli\u003eUpgrading existing solar power systems with a battery (AC or DC coupled)\u003c\/li\u003e\n\n\u003cli\u003eEmergency power and backup during power outages\u003c\/li\u003e\n\n\u003cli\u003eLoad shifting – charge the battery when power is cheap and use it when prices peak\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eBattery type\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eLead-acid or lithium-ion\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eBattery voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e40-60 V\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. charge\/discharge current\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e135 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eCharging strategy for lithium battery\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eAutomatic adaptation to BMS\u003c\/td\u003e\n\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eNumber of battery inputs\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e1\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. connected PV power\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e12,000 W\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. PV input power\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e9,600 W\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. PV input voltage\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e500 V\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eStart-up voltage\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e125 V\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMPPT voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e150-425 V\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eRated PV input voltage\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e370 V\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. PV operating current\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e18+18 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. short-circuit current, input\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e27+27 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eNumber of MPPT \/ strings per MPPT\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e2\/1+1\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eRated AC input\/output power\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e6,000 W\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. AC input\/output power (VA)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e6,600 VA\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eRated AC input\/output current\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e27.3\/26.1 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. AC input\/output current\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e30\/28.7 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. continuous AC pass-through (grid to load)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e40 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003ePeak power (off-grid)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e2 × rated power for 10 s\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eRated input\/output voltage\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e220V\/230V 0.85Un-1.1Un L+N+PE\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eRated grid frequency \/ range\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e50\/45-55, 60\/55-65 Hz\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003ePower factor, adjustment range\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e0.8 leading – 0.8 lagging\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eHarmonic current distortion (THDi)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e\u0026lt;3% (of rated power)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eDC injection current\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e\u0026lt;0.5%ln\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. efficiency\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e97.6%\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eEuro-efficiency\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e96.5%\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMPPT efficiency\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e\u0026gt;99%\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eBuilt-in protection\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eReverse DC polarity protection, AC output overcurrent protection, thermal protection, AC output overvoltage protection, AC output short-circuit protection, DC component monitoring, arc fault detection (AFCI) (optional), anti-islanding protection, DC switch, insulation monitoring, residual current monitoring\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eSurge protection\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eType II (DC), Type II (AC)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eLCD display\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eCommunication interface\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eWiFi, RS485, CAN\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e-40 to +60°C, \u0026gt;45°C derating\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003ePermissible humidity\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e0~100%\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. installation altitude\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e2,000 m\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eNoise level\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e\u0026lt;45 dB\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eProtection class (IP)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eIP65\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eInverter topology\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eNon-isolated (solar), isolated (battery)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eOvervoltage category\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eOVC II (DC), OVC III (AC)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eDimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e330×580×232 (excl. connectors and brackets)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e24.9 kg\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e5 years \/ 10 years (warranty period depends on the inverter installation site – see Deye’s warranty policy)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eCooling\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eIntelligent air cooling\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eGrid standards\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eIEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eSafety \/ EMC standards\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eIEC\/EN 61000-6-1\/2\/3\/4, IEC\/EN 62109-1, IEC\/EN 62109-2\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eItem number: SUN-6K-SG05LP1-EU-AM2-P\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/www.deyeinverter.com\/deyeinverter\/2026\/04\/24\/BDatasheetSUN-36-10K-SG05LP1-EU-AM2-P20260424en-7f2j.pdf\" target=\"_blank\" rel=\"noopener\"\u003eDownload datasheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/www.deyeinverter.com\/product\/single-phase-low-voltage-hybrid-inverter\/sun3-6-5-6-7-7-6-8-10ksg05lp1euam2p-3-610kw-single-phase-2-mppt-hybrid-inverter-lv-battery-supported.html\" target=\"_blank\" rel=\"noopener\"\u003eOfficial product page at Deye\u003c\/a\u003e\u003c\/p\u003e","brand":"Deye","offers":[{"title":"Default Title","offer_id":65807943729501,"sku":"SUN-6K-SG05LP1-EU-AM2-P","price":7899.0,"currency_code":"DKK","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1022\/7649\/7757\/files\/SUN-3.6-10K-SG05LP1-EU_376d181d-2498-4375-a37c-cd01cd675927.png?v=1788495568","url":"https:\/\/lithiumpro.dk\/en\/products\/deye-sun-6k-sg05lp1-hybrid-inverter-1-faset","provider":"LithiumPro","version":"1.0","type":"link"}