{"product_id":"deye-sun-20k-sg05lp3-eu-sm2","title":"Deye SUN-20K-SG05LP3-EU-SM2 hybrid inverter 20 kW 3-phase","description":"\u003ch2\u003eDeye SUN-20K-SG05LP3-EU-SM2 hybrid inverter 20 kW 3-phase – solar inverter, battery charger and backup power in one unit.\u003c\/h2\u003e\u003cp\u003eThe Deye SUN-20K-SG05LP3-EU-SM2 is a 20 kW 3-phase hybrid inverter that combines a solar inverter, battery charger and backup power supply in one unit. With 2 MPPT trackers and up to 40,000 W of connected PV power, it can both work together with the grid and keep powering the house if there is a power cut. This means you store your own solar power in the battery and use it when you actually need it – instead of selling it cheaply to the grid.\u003c\/p\u003e\u003ch3\u003eBenefits\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eRated power 20,000 W\u003c\/li\u003e\n\u003cli\u003e2 independent MPPT trackers for flexible string configuration\u003c\/li\u003e\n\u003cli\u003eUp to 40,000 W of PV power can be connected\u003c\/li\u003e\n\u003cli\u003eMax. charge\/discharge current of 350 A to the battery\u003c\/li\u003e\n\u003cli\u003ePeak power in off-grid mode: 2 × rated power for 10 s\u003c\/li\u003e\n\u003cli\u003eEfficiency up to 97.6 %\u003c\/li\u003e\n\u003cli\u003eIP65 protection rating – can be installed outdoors\u003c\/li\u003e\n\u003cli\u003eBuilt-in LCD display for local operation and monitoring\u003c\/li\u003e\n\u003cli\u003eCommunication via WiFi, RS485, CAN\u003c\/li\u003e\n\u003cli\u003eReady for remote monitoring via Deye Cloud \/ SOLARMAN (requires data logger)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSolar PV systems with battery storage in private homes and small businesses\u003c\/li\u003e\n\u003cli\u003eUpgrading existing solar PV systems with a battery (AC- or DC-coupled)\u003c\/li\u003e\n\u003cli\u003eBackup power during power cuts\u003c\/li\u003e\n\u003cli\u003eLoad shifting – charge the battery when electricity is cheap, and use it when the price peaks\u003c\/li\u003e\n\u003cli\u003eThree-phase installations, including those with unbalanced loads between the phases\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLead-acid or lithium-ion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40-60 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. charge\/discharge current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e350 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCharging strategy for lithium battery\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic adaptation to BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of battery inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. connected PV power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40,000 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. PV input power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32,000 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. PV input voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStart-up voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMPPT voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160-650 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated PV input voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e550 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. PV operating current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36+36 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. short-circuit current, input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e54+54 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of MPPTs \/ strings per MPPT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\/2+2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated AC input\/output power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20,000 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. AC input\/output power (VA)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22,000 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated AC input\/output current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30.4\/29 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. AC input\/output current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e33.4\/31.9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. continuous AC pass-through (grid to load)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePeak power (off-grid mode)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 × rated power for 10 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower factor, adjustment range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.8 leading to 0.8 lagging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated input\/output voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e220\/380V, 230\/400V 0.85Un-1.1Un 3L+N+PE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated grid frequency \/ range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/45-55, 60\/55-65 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal harmonic current distortion (THDi)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;3 % (of rated power)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDC injection into grid\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;0.5 % In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. efficiency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e97,6 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEuro efficiency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e97,0 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMPPT efficiency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;99 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuilt-in protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC reverse polarity protection, AC output overcurrent protection, thermal protection, AC output overvoltage protection, AC output short-circuit protection, DC component monitoring, load overvoltage protection, earth fault monitoring, arc fault detection (AFCI) (optional), grid monitoring, islanding monitoring, earth fault detection, DC input switch, insulation monitoring on DC terminals, residual current detection (RCD), surge protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSurge protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eType II(DC), Type II(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLCD display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWiFi, RS485, CAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 to +60°C, \u0026gt;45°C derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePermitted humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0-100 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. installation altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3,000m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNoise level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e＜60 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection rating (IP)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInverter topology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNon-isolated (PV), isolated (battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOVC II(DC), OVC III(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e456×750×268.5 (excl. connectors and bracket)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e51.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntelligent air cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 years \/ 10 years (the warranty period depends on where the inverter is installed – see Deye's warranty policy)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGrid standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety \/ EMC standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61000-6-1\/2\/3\/4, IEC\/EN 62109-1, IEC\/EN 62109-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eItem number: SUN-20K-SG05LP3-EU-SM2\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/www.deyeinverter.com\/deyeinverter\/2026\/04\/26\/BDatasheetSUN-14-20K-SG05LP3-EU-SM220260424en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eDownload datasheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/www.deyeinverter.com\/product\/three-phase-hybrid-inverter-1\/sun14-15-16-18-20ksg05lp3eusm2-1420kw-three-phase-2-mppt-hybrid-inverter-lv-battery-supported.html\" target=\"_blank\" rel=\"noopener\"\u003eOfficial product page at Deye\u003c\/a\u003e\u003c\/p\u003e","brand":"Deye","offers":[{"title":"Default Title","offer_id":63019355537757,"sku":"SUN-20K-SG05LP3-EU-SM2","price":23000.0,"currency_code":"DKK","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1022\/7649\/7757\/files\/Deyeforfra.jpg?v=1767466625","url":"https:\/\/lithiumpro.dk\/en\/products\/deye-sun-20k-sg05lp3-eu-sm2","provider":"LithiumPro","version":"1.0","type":"link"}