{"product_id":"deye-sun-16k-sg01lp1-eu-hybrid-inverter-16-kw-1-faset","title":"Deye SUN-16K- SG01LP1-EU hybrid inverter 16 kW 1-phase","description":"\u003ch2\u003eDeye SUN-16K -SG01LP1-EU hybrid inverter 16 kW 1-phase – PV inverter, battery charger and emergency power in one unit.\u003c\/h2\u003e\u003cp\u003eThe Deye SUN-16K-SG01LP1-EU is a 16 kW 1-phase hybrid inverter that combines a solar PV inverter, battery charger, and emergency power supply in one unit. With 3 MPPT trackers and up to 32,000 W of connected solar power, it can both work in tandem with the power grid and continue to supply power to the house if the grid goes down. This means you store your own solar energy in the battery and use it when you actually need it – instead of selling it cheaply to the grid.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\n\u003cli\u003eNominal power 16,000 W\u003c\/li\u003e\n\n\u003cli\u003e3 independent MPPT trackers for flexible string configuration\u003c\/li\u003e\n\n\u003cli\u003eUp to 32,000 W of solar power can be connected\u003c\/li\u003e\n\n\u003cli\u003eMax. charge\/discharge current 290 A to the battery\u003c\/li\u003e\n\n\u003cli\u003ePeak power in off-grid mode: 2 × nominal power for 10 s\u003c\/li\u003e\n\n\u003cli\u003eEfficiency up to 97.6%\u003c\/li\u003e\n\n\u003cli\u003eIngress protection rating IP65 – can be mounted outdoors\u003c\/li\u003e\n\n\u003cli\u003eBuilt-in LCD display for local operation and monitoring\u003c\/li\u003e\n\n\u003cli\u003eCommunication via WiFi, RS485, CAN\u003c\/li\u003e\n\n\u003cli\u003eReady for remote monitoring via Deye Cloud \/ SOLARMAN (requires data logger)\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\n\u003cli\u003eSolar power systems with battery storage for private homes and small businesses\u003c\/li\u003e\n\n\u003cli\u003eUpgrading existing solar power systems with a battery (AC- or DC-coupled)\u003c\/li\u003e\n\n\u003cli\u003eEmergency power and backup in case of power failure\u003c\/li\u003e\n\n\u003cli\u003eLoad shifting – charge the battery when power is cheap and use it when prices peak\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eBattery type\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eLead-acid or lithium-ion\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eBattery voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e40-60 V\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. charge\/discharge current\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e290 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eCharging strategy for lithium battery\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eAutomatic adaptation to BMS\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eNumber of battery inputs\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e1\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. connected PV power\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e32,000 W\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. PV input power\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e25,600 W\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. PV input voltage\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e500 V\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eStart-up voltage\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e125 V\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMPPT voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e150-425 V\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eNominal PV input voltage\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e370 V\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. PV operating current\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e36+36+36 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. short-circuit current, input\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e54+54+54 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eNumber of MPPT \/ strings per MPPT\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e3\/2+2+2\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eNominal AC input\/output power\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e16,000 W\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. AC input\/output power (VA)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e17,600 VA\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eNominal AC input\/output current\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e72.8\/69.6 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. AC input\/output current\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e80\/76.6 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. continuous AC pass-through (grid to consumption)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e100 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003ePeak power (off-grid)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e2 × nominal power for 10 s\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003ePower factor, adjustment range\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e0.8 capacitive to 0.8 inductive\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eNominal input\/output voltage\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e220\/230V 0.85Un-1.1Un L+N+PE\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eNominal grid frequency \/ range\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e50\/45-55, 60\/55-65 Hz\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eHarmonic current distortion (THDi)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e\u0026lt;3% (at nominal power)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eDC injection current\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e\u0026lt;0.5%In\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. efficiency\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e97.6%\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eEuro efficiency\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e96.5%\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMPPT efficiency\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e＞99%\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eIntegrated protection\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eReverse DC polarity protection, AC output overcurrent protection, thermal protection, AC output overvoltage protection, AC output short-circuit protection, DC component monitoring, arc fault detection (AFCI) (optional), anti-islanding protection, DC switch, insulation monitoring, residual current monitoring\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eSurge protection\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eType II(DC), Type II(AC)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eLCD display\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eCommunication interface\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eWiFi, RS485, CAN\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e-40 to +60°C, \u0026gt;45°C power derating\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003ePermissible humidity\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e0~100%\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. installation altitude\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e3,000 m\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eNoise level\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e＜55 dB\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eIngress protection (IP)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eIP65\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eInverter topology\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eNon-isolated (PV), isolated (battery)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eOvervoltage category\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eOVC II(DC), OVC III(AC)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eDimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e464×763×282 (excl. connectors and brackets)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e54.1 kg\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e5 years \/ 10 years (warranty period depends on the inverter's installation location – see Deye's warranty policy)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eCooling\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eIntelligent air cooling\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eGrid standards\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eIEC 61727, IEC 62116, AS 4777.2, NRS 097\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eSafety \/ EMC standards\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eIEC\/EN 61000-6-1\/2\/3\/4, IEC\/EN 62109-1, IEC\/EN 62109-2\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eItem number: SUN-16K-SG01LP1-EU\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/www.deyeinverter.com\/deyeinverter\/2026\/08\/10\/BDatasheetSUN-12-18K-SG01LP1-EU-AM3-P20260810en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eDownload datasheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/www.deyeinverter.com\/product\/single-phase-low-voltage-hybrid-inverter\/sun12-14-16-18ksg01lp1euam3p.html\" target=\"_blank\" rel=\"noopener\"\u003eOfficial product page at Deye\u003c\/a\u003e\u003c\/p\u003e","brand":"Deye","offers":[{"title":"Default Title","offer_id":65807943860573,"sku":"SUN-16K-SG01LP1-EU","price":19299.0,"currency_code":"DKK","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1022\/7649\/7757\/files\/12-18.png?v=1788495568","url":"https:\/\/lithiumpro.dk\/en\/products\/deye-sun-16k-sg01lp1-eu-hybrid-inverter-16-kw-1-faset","provider":"LithiumPro","version":"1.0","type":"link"}