{"product_id":"deye-sun-10k-sg05lp3-hybrid-inverter-3-faset","title":"Deye SUN-10K-SG05LP3-EU-SM2 hybrid inverter 10 kW 3-phase","description":"\u003ch2\u003eDeye SUN-10K-SG05LP3-EU-SM2 hybrid inverter 10 kW 3-phase – solar inverter, battery charger, and emergency power in one unit.\u003c\/h2\u003e\u003cp\u003eThe Deye SUN-10K-SG05LP3-EU-SM2 is a 10 kW 3-phase hybrid inverter that combines a solar inverter, battery charger, and emergency power supply in one unit. With 2 MPPT trackers and up to 20,000 W of connected solar power, it can operate in tandem with the electrical grid and continue to power the house if the power goes out. This means you store your own solar energy in the battery and use it when you actually need it – instead of selling it cheaply to the grid.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\n\u003cli\u003eRated power 10,000 W\u003c\/li\u003e\n\n\u003cli\u003e2 independent MPPT trackers for flexible string configuration\u003c\/li\u003e\n\n\u003cli\u003eUp to 20,000 W of solar power can be connected\u003c\/li\u003e\n\n\u003cli\u003eMax. charging\/discharging current 210 A for battery\u003c\/li\u003e\n\n\u003cli\u003ePeak power in off-grid operation: 2 × rated power for 10 s\u003c\/li\u003e\n\n\u003cli\u003eEfficiency up to 97.6%\u003c\/li\u003e\n\n\u003cli\u003eIngress protection IP65 – can be installed outdoors\u003c\/li\u003e\n\n\u003cli\u003eBuilt-in LCD display for local operation and monitoring\u003c\/li\u003e\n\n\u003cli\u003eCommunication via WiFi, RS485, CAN\u003c\/li\u003e\n\n\u003cli\u003eReady for remote monitoring via Deye Cloud \/ SOLARMAN (requires data logger)\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003ch3\u003eApplication\u003c\/h3\u003e\u003cul\u003e\n\n\u003cli\u003eSolar power systems with battery storage for private homes and small businesses\u003c\/li\u003e\n\n\u003cli\u003eUpgrading existing solar power systems with a battery (AC or DC coupled)\u003c\/li\u003e\n\n\u003cli\u003eEmergency power and backup during power outages\u003c\/li\u003e\n\n\u003cli\u003eLoad shifting – charge the battery when electricity is cheap and use it when prices peak\u003c\/li\u003e\n\n\u003cli\u003eThree-phase installations, including with unbalanced loads between phases\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eBattery type\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eLead-acid or lithium-ion\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eBattery voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e40-60 V\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. charging\/discharging current\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e210 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eCharging strategy for lithium battery\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eAutomatic adaptation to BMS\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eNumber of battery inputs\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e1\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. connected PV power\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e20,000 W\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. PV input power\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e16,000 W\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. PV input voltage\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e800 V\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eStart-up voltage\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e160 V\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMPPT voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e200-650 V\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eRated PV input voltage\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e550 V\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. PV operating current\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e26+26 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. short-circuit current, input\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e39+39 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eNumber of MPPT \/ strings per MPPT\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e2\/2+2\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eRated AC input\/output power\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e10,000 W\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. AC input\/output power (VA)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e11,000 VA\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eRated AC input\/output current\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e15.2\/14.5 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. AC input\/output current\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e16.7\/16 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. continuous AC pass-through (grid to load)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e45 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003ePeak power (off-grid)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e2 × rated power for 10 s\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003ePower factor, adjustment range\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e0.8 leading to 0.8 lagging\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eRated input\/output voltage\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e220\/380V, 230\/400V 0.85Un-1.1Un 3L+N+PE\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eRated grid frequency \/ range\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e50\/45-55, 60\/55-65 Hz\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eHarmonic current distortion (THDi)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e\u0026lt;3% (at rated power)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eDC injection current\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e\u0026lt;0.5% In\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. efficiency\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e97.6%\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eEuro-efficiency\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e97.0%\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMPPT efficiency\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e\u0026gt;99%\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eBuilt-in protection\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eDC reverse polarity protection, AC output overcurrent protection, thermal protection, AC output overvoltage protection, AC output short-circuit protection, DC component monitoring, arc fault detection (AFCI) (optional), anti-islanding protection, DC switch, insulation monitoring, residual current monitoring\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eSurge protection\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eType II(DC), Type II(AC)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eLCD display\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eCommunication interface\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eWiFi, RS485, CAN\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e-40 to +60°C, \u0026gt;45°C derating\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003ePermissible humidity\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e0-100%\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. installation altitude\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e3,000m\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eNoise level\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e≤55 dB\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eIngress protection (IP)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eIP65\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eInverter topology\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eNon-isolated (solar), isolated (battery)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eOvervoltage category\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eOVC II(DC), OVC III(AC)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eDimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e386×660×250 (excl. connectors and brackets)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e35.2 kg\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eCooling\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eIntelligent air cooling\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e5 years \/ 10 years (warranty period depends on the inverter's installation location – see Deye's warranty policy)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eGrid standards\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eIEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eSafety \/ EMC standards\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eIEC\/EN 61000-6-1\/2\/3\/4, IEC\/EN 62109-1, IEC\/EN 62109-2\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eItem number: SUN-10K-SG05LP3-EU-SM2\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/www.deyeinverter.com\/deyeinverter\/2026\/04\/25\/BDatasheetSUN-3-12K-SG05LP3-EU-SM220260424en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eDownload datasheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/www.deyeinverter.com\/product\/three-phase-hybrid-inverter-1\/sun3-4-5-6-8-10-12ksg05lp3eusm2-312kw-three-phase-2-mppt-hybrid-inverter-lv-battery-supported.html\" target=\"_blank\" rel=\"noopener\"\u003eOfficial product page at Deye\u003c\/a\u003e\u003c\/p\u003e","brand":"Deye","offers":[{"title":"Default Title","offer_id":65807943991645,"sku":"SUN-10K-SG05LP3-EU-SM2","price":16099.0,"currency_code":"DKK","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1022\/7649\/7757\/files\/12_64a3cac3-ba2c-4114-b1ac-d3f0e5b28d52.png?v=1788495572","url":"https:\/\/lithiumpro.dk\/en\/products\/deye-sun-10k-sg05lp3-hybrid-inverter-3-faset","provider":"LithiumPro","version":"1.0","type":"link"}