{"title":"Deye Hybrid Inverters 1-phase","description":"\u003cp\u003eDeye hybrid inverters for single-phase connection, typically for detached houses and smaller installations. Choose your model based on power output in kW and battery voltage – the hybrid inverter manages solar panels, battery, and grid in one unit.\u003c\/p\u003e","products":[{"product_id":"deye-sun-3-6k-sg05lp1-hybrid-inverter-1-faset","title":"Deye SUN-3.6K-SG05LP1-EU-AM2-P hybrid inverter 3.6 kW 1-phase","description":"\u003ch2\u003eDeye SUN-3.6K-SG05LP1-EU-AM2-P hybrid inverter 3.6 kW single-phase – solar inverter, battery charger and emergency power in one unit.\u003c\/h2\u003e\u003cp\u003eThe Deye SUN-3.6K-SG05LP1-EU-AM2-P is a 3.6 kW single-phase hybrid inverter that combines a solar inverter, battery charger, and emergency power supply in one unit. With 2 MPPT trackers and up to 7,200 W of connected solar power, it can both work with the grid and continue to power the house if the power goes out. This means you store your own solar energy in the battery and use it when you need it yourself – instead of selling it cheaply to the grid.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\n\u003cli\u003eNominal power 3,600 W\u003c\/li\u003e\n\n\u003cli\u003e2 independent MPPT trackers for flexible string configuration\u003c\/li\u003e\n\n\u003cli\u003eUp to 7,200 W of solar power can be connected\u003c\/li\u003e\n\n\u003cli\u003eMax. charge\/discharge current 90 A for the battery\u003c\/li\u003e\n\n\u003cli\u003ePeak power in off-grid mode: 2 × nominal power for 10 s\u003c\/li\u003e\n\n\u003cli\u003eEfficiency up to 97.6 %\u003c\/li\u003e\n\n\u003cli\u003eIngress protection IP65 – can be mounted outdoors\u003c\/li\u003e\n\n\u003cli\u003eBuilt-in LCD display for local operation and monitoring\u003c\/li\u003e\n\n\u003cli\u003eCommunication via WiFi, RS485, CAN\u003c\/li\u003e\n\n\u003cli\u003eReady for remote monitoring via Deye Cloud \/ SOLARMAN (requires data logger)\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003ch3\u003eApplication\u003c\/h3\u003e\u003cul\u003e\n\n\u003cli\u003eSolar PV systems with battery storage in private homes and small businesses\u003c\/li\u003e\n\n\u003cli\u003eUpgrading existing solar PV systems with battery (AC- or DC-coupled)\u003c\/li\u003e\n\n\u003cli\u003eEmergency power and backup during power outages\u003c\/li\u003e\n\n\u003cli\u003eLoad shifting – charge the battery when electricity is cheap and use it when prices peak\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eBattery type\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eLead-acid or lithium-ion\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eBattery voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e40-60 V\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. charge\/discharge current\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e90 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eLithium battery charging strategy\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eAutomatic adaptation to BMS\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eNumber of battery inputs\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e1\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. connected PV power\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e7,200 W\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. PV input power\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e5,760 W\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. PV input voltage\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e500 V\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eStart-up voltage\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e125 V\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMPPT voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e150-425 V\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eNominal PV input voltage\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e370 V\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. PV operating current\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e18+18 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. short-circuit current, input\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e27+27 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eNumber of MPPT \/ strings per MPPT\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e2\/1+1\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eNominal AC input\/output power\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e3,600 W\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. AC input\/output power (VA)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e3,960 VA\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eNominal AC input\/output current\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e16.4\/15.7 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. AC input\/output current\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e18\/17.2 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. continuous AC pass-through (grid to load)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e35 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003ePeak power (off-grid)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e2 × nominal power for 10 s\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eNominal input\/output voltage\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e220V\/230V 0.85Un-1.1Un L+N+PE\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eNominal grid frequency \/ range\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e50\/45-55，60\/55-65 Hz\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003ePower factor, adjustment range\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e0.8 leading – 0.8 lagging\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eHarmonic current distortion (THDi)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e\u0026lt;3 % (of nominal power)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eDC injection current\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e\u0026lt;0.5 %ln\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. efficiency\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e97.6 %\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eEuro-efficiency\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e96.5 %\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMPPT efficiency\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e＞99 %\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eIntegrated protection\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eDC reverse polarity protection, AC output overcurrent protection, thermal protection, AC output overvoltage protection, AC output short-circuit protection, DC component monitoring, arc fault detection (AFCI) (optional), anti-islanding protection, DC switch, insulation monitoring, residual current monitoring\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eSurge protection\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eType II(DC), Type II(AC)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eLCD display\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eCommunication interface\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eWiFi, RS485, CAN\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e-40 to +60°C, \u0026gt;45°C derating\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003ePermissible humidity\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e0~100 %\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. installation altitude\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e2,000m\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eNoise level\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e＜45 dB\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eIngress protection (IP)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eIP65\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eInverter topology\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eNon-isolated (solar), isolated (battery)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eOvervoltage category\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eOVC II(DC), OVC III(AC)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eDimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e330×580×232 (excl. connectors and brackets)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e24.9 kg\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e5 years \/ 10 years (warranty period depends on the inverter's installation location – see Deye's warranty policy)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eCooling\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eIntelligent air cooling\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eGrid standards\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eIEC 61727, IEC 62116, CEI 0-21, EN 50549，NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eSafety \/ EMC standards\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eIEC\/EN 61000-6-1\/2\/3\/4, IEC\/EN 62109-1, IEC\/EN 62109-2\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eItem number: SUN-3.6K-SG05LP1-EU-AM2-P\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/www.deyeinverter.com\/deyeinverter\/2026\/04\/24\/BDatasheetSUN-36-10K-SG05LP1-EU-AM2-P20260424en-7f2j.pdf\" target=\"_blank\" rel=\"noopener\"\u003eDownload datasheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/www.deyeinverter.com\/product\/single-phase-low-voltage-hybrid-inverter\/sun3-6-5-6-7-7-6-8-10ksg05lp1euam2p-3-610kw-single-phase-2-mppt-hybrid-inverter-lv-battery-supported.html\" target=\"_blank\" rel=\"noopener\"\u003eOfficial product page at Deye\u003c\/a\u003e\u003c\/p\u003e","brand":"Deye","offers":[{"title":"Default Title","offer_id":65807943303517,"sku":"SUN-3.6K-SG05LP1-EU-AM2-P","price":7499.0,"currency_code":"DKK","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1022\/7649\/7757\/files\/SUN-3.6-10K-SG05LP1-EU.png?v=1788495540"},{"product_id":"deye-sun-8k-sg05lp1-hybrid-inverter-1-faset","title":"Deye SUN-8K-SG05LP1-EU-AM2-P hybrid inverter 8 kW 1-phase","description":"\u003ch2\u003eDeye SUN-8K-SG05LP1-EU-AM2-P hybrid inverter 8 kW single-phase – PV inverter, battery charger and emergency power in one unit.\u003c\/h2\u003e\u003cp\u003eThe Deye SUN-8K-SG05LP1-EU-AM2-P is an 8 kW single-phase hybrid inverter that combines a PV inverter, battery charger, and emergency power supply into one unit. With 2 MPPT trackers and up to 16,000 W of connected solar power, it can operate in parallel with the grid and continue to power the house in the event of a power outage. This means you store your own solar energy in the battery and use it when you actually need it – instead of selling it cheaply to the grid.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\n\u003cli\u003eNominal power 8,000 W\u003c\/li\u003e\n\n\u003cli\u003e2 independent MPPT trackers for flexible string configuration\u003c\/li\u003e\n\n\u003cli\u003eUp to 16,000 W of solar power can be connected\u003c\/li\u003e\n\n\u003cli\u003eMax. charge\/discharge current 190 A for the battery\u003c\/li\u003e\n\n\u003cli\u003ePeak power in island mode: 2 × nominal power for 10 s\u003c\/li\u003e\n\n\u003cli\u003eEfficiency up to 97.6 %\u003c\/li\u003e\n\n\u003cli\u003eIP65 ingress protection – suitable for outdoor installation\u003c\/li\u003e\n\n\u003cli\u003eBuilt-in LCD display for local operation and monitoring\u003c\/li\u003e\n\n\u003cli\u003eCommunication via WiFi, RS485, CAN\u003c\/li\u003e\n\n\u003cli\u003eReady for remote monitoring via Deye Cloud \/ SOLARMAN (requires data logger)\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003ch3\u003eApplication\u003c\/h3\u003e\u003cul\u003e\n\n\u003cli\u003eSolar PV systems with battery storage for private homes and small businesses\u003c\/li\u003e\n\n\u003cli\u003eUpgrading existing solar PV systems with a battery (AC or DC coupled)\u003c\/li\u003e\n\n\u003cli\u003eEmergency power and backup during power outages\u003c\/li\u003e\n\n\u003cli\u003eLoad shifting – charge the battery when electricity is cheap and use it when prices peak\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eBattery type\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eLead-acid or lithium-ion\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eBattery voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e40-60 V\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. charge\/discharge current\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e190 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eCharging strategy for lithium battery\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eAutomatic adaptation to BMS\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eNumber of battery inputs\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e1\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. connected PV power\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e16,000 W\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. PV input power\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e12,800 W\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. PV input voltage\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e500 V\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eStart-up voltage\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e125 V\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMPPT voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e150-425 V\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eNominal PV input voltage\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e370 V\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. PV operating current\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e32+32 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. short-circuit current, input\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e48+48 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eNumber of MPPT \/ strings per MPPT\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e2\/2+2\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eNominal AC input\/output power\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e8,000 W\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. AC input\/output power (VA)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e8,800 VA\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eNominal AC input\/output current\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e36.4\/34.8 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. AC input\/output current\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e40\/38.3 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. continuous AC pass-through (grid to load)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e50 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003ePeak power (island mode)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e2 × nominal power for 10 s\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eNominal input\/output voltage\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e220V\/230V 0.85Un-1.1Un L+N+PE\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eNominal grid frequency \/ range\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e50\/45-55, 60\/55-65 Hz\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003ePower factor, adjustment range\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e0.8 capacitive – 0.8 inductive\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eHarmonic current distortion (THDi)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e\u0026lt;3 % (of nominal power)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eDC injection current\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e\u0026lt;0.5 %ln\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. efficiency\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e97.6 %\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eEuro efficiency\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e96.5 %\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMPPT efficiency\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e＞99 %\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eBuilt-in protection\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eDC reverse polarity protection, AC output overcurrent protection, thermal protection, AC output overvoltage protection, AC output short-circuit protection, DC component monitoring, arc fault detection (AFCI) (optional), islanding protection, DC switch, insulation monitoring, residual current monitoring\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eSurge protection\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eType II(DC), Type II(AC)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eLCD display\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eCommunication interface\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eWiFi, RS485, CAN\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e-40 to +60°C, \u0026gt;45°C power derating\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003ePermitted humidity\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e0~100 %\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. installation altitude\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e2,000m\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eNoise level\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e＜45 dB\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eIngress protection (IP)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eIP65\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eInverter topology\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eNon-isolated (solar), isolated (battery)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eOvervoltage category\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eOVC II(DC), OVC III(AC)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eDimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e330×580×232 (excl. connectors and brackets)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e24.9 kg\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e5 years \/ 10 years (warranty period depends on the inverter's installation location – see Deye's warranty policy)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eCooling\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eIntelligent air cooling\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eGrid standards\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eIEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eSafety \/ EMC standards\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eIEC\/EN 61000-6-1\/2\/3\/4, IEC\/EN 62109-1, IEC\/EN 62109-2\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eItem number: SUN-8K-SG05LP1-EU-AM2-P\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/www.deyeinverter.com\/deyeinverter\/2026\/04\/24\/BDatasheetSUN-36-10K-SG05LP1-EU-AM2-P20260424en-7f2j.pdf\" target=\"_blank\" rel=\"noopener\"\u003eDownload datasheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/www.deyeinverter.com\/product\/single-phase-low-voltage-hybrid-inverter\/sun3-6-5-6-7-7-6-8-10ksg05lp1euam2p-3-610kw-single-phase-2-mppt-hybrid-inverter-lv-battery-supported.html\" target=\"_blank\" rel=\"noopener\"\u003eOfficial product page at Deye\u003c\/a\u003e\u003c\/p\u003e","brand":"Deye","offers":[{"title":"Default Title","offer_id":65807943663965,"sku":"SUN-8K-SG05LP1-EU-AM2-P","price":11199.0,"currency_code":"DKK","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1022\/7649\/7757\/files\/SUN-3.6-10K-SG05LP1-EU_6a486ed8-2d75-4e33-b489-c283c6785810.png?v=1788495568"},{"product_id":"deye-sun-5k-sg05lp1-hybrid-inverter-1-faset","title":"Deye SUN-5K-SG05LP1-EU-AM2-P hybrid inverter 5 kW 1-phase","description":"\u003ch2\u003eDeye SUN-5K-SG05LP1-EU-AM2-P hybrid inverter 5 kW single-phase – solar inverter, battery charger, and emergency power in one unit.\u003c\/h2\u003e\u003cp\u003eThe Deye SUN-5K-SG05LP1-EU-AM2-P is a 5 kW single-phase hybrid inverter that combines a solar inverter, battery charger, and emergency power supply in one unit. With 2 MPPT trackers and up to 10,000 W of connected solar power, it can both work with the grid and power the house if the power goes out. This means you store your own solar power in the battery and use it when you need it – instead of selling it cheaply to the grid.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\n\u003cli\u003eNominal power 5,000 W\u003c\/li\u003e\n\n\u003cli\u003e2 independent MPPT trackers for flexible string configuration\u003c\/li\u003e\n\n\u003cli\u003eUp to 10,000 W of solar power can be connected\u003c\/li\u003e\n\n\u003cli\u003eMax. charge\/discharge current 120 A for the battery\u003c\/li\u003e\n\n\u003cli\u003ePeak power in island mode: 2 × nominal power for 10 s\u003c\/li\u003e\n\n\u003cli\u003eEfficiency up to 97.6%\u003c\/li\u003e\n\n\u003cli\u003eIP65 protection rating – can be mounted outdoors\u003c\/li\u003e\n\n\u003cli\u003eBuilt-in LCD display for local operation and monitoring\u003c\/li\u003e\n\n\u003cli\u003eCommunication via WiFi, RS485, CAN\u003c\/li\u003e\n\n\u003cli\u003eReady for remote monitoring via Deye Cloud \/ SOLARMAN (requires data logger)\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003ch3\u003eApplication\u003c\/h3\u003e\u003cul\u003e\n\n\u003cli\u003eSolar power systems with battery storage in private homes and small businesses\u003c\/li\u003e\n\n\u003cli\u003eUpgrading existing solar power systems with a battery (AC or DC coupled)\u003c\/li\u003e\n\n\u003cli\u003eEmergency power and backup during power outages\u003c\/li\u003e\n\n\u003cli\u003eLoad shifting – charge the battery when power is cheap, and use it when prices peak\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eBattery type\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eLead-acid or lithium-ion\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eBattery voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e40-60 V\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. charge\/discharge current\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e120 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eCharging strategy for lithium battery\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eAutomatic adaptation to BMS\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eNumber of battery inputs\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e1\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. connected PV power\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e10,000 W\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. PV input power\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e8,000 W\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. PV input voltage\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e500 V\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eStart-up voltage\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e125 V\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMPPT voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e150-425 V\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eNominal PV input voltage\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e370 V\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. PV operating current\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e18+18 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. short-circuit current, input\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e27+27 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eNumber of MPPT \/ strings per MPPT\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e2\/1+1\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eNominal AC input\/output power\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e5,000 W\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. AC input\/output power (VA)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e5,500 VA\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eNominal AC input\/output current\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e22.7\/21.7 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. AC input\/output current\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e25\/23.9 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. continuous AC pass-through (grid to load)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e35 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003ePeak power (island mode)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e2 × nominal power for 10 s\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eNominal input\/output voltage\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e220V\/230V 0.85Un-1.1Un L+N+PE\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eNominal grid frequency \/ range\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e50\/45-55, 60\/55-65 Hz\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003ePower factor, adjustment range\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e0.8 leading – 0.8 lagging\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eTotal harmonic distortion (THDi)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e\u0026lt;3% (of nominal power)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eDC injection current\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e\u0026lt;0.5% In\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. efficiency\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e97.6%\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eEuro efficiency\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e96.5%\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMPPT efficiency\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e\u0026gt;99%\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eBuilt-in protection\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eDC reverse polarity protection, AC output overcurrent protection, thermal protection, AC output overvoltage protection, AC output short-circuit protection, DC component monitoring, arc fault detection (AFCI) (optional), islanding protection, DC switch, insulation monitoring, residual current monitoring\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eOvervoltage protection\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eType II (DC), Type II (AC)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003c!--nl --\u003e\u003ctd\u003eLCD display\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eCommunication interface\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eWiFi, RS485, CAN\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e-40 to +60°C, \u0026gt;45°C power derating\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003ePermissible humidity\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e0~100%\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. installation altitude\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e2,000m\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eNoise level\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e\u0026lt;45 dB\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eProtection rating (IP)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eIP65\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eInverter topology\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eNon-isolated (solar), isolated (battery)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eOvervoltage category\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eOVC II (DC), OVC III (AC)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eDimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e330×580×232 (excl. connectors and brackets)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e24.9 kg\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e5 years \/ 10 years (warranty period depends on the inverter's installation location – see Deye's warranty policy)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eCooling\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eIntelligent air cooling\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eGrid standards\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eIEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eSafety \/ EMC standards\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eIEC\/EN 61000-6-1\/2\/3\/4, IEC\/EN 62109-1, IEC\/EN 62109-2\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eItem number: SUN-5K-SG05LP1-EU-AM2-P\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/www.deyeinverter.com\/deyeinverter\/2026\/04\/24\/BDatasheetSUN-36-10K-SG05LP1-EU-AM2-P20260424en-7f2j.pdf\" target=\"_blank\" rel=\"noopener\"\u003eDownload datasheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/www.deyeinverter.com\/product\/single-phase-low-voltage-hybrid-inverter\/sun3-6-5-6-7-7-6-8-10ksg05lp1euam2p-3-610kw-single-phase-2-mppt-hybrid-inverter-lv-battery-supported.html\" target=\"_blank\" rel=\"noopener\"\u003eOfficial product page at Deye\u003c\/a\u003e\u003c\/p\u003e","brand":"Deye","offers":[{"title":"Default Title","offer_id":65807943696733,"sku":"SUN-5K-SG05LP1-EU-AM2-P","price":7799.0,"currency_code":"DKK","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1022\/7649\/7757\/files\/SUN-3.6-10K-SG05LP1-EU_028f9bf4-bde7-4226-bbd9-b0cd1b80c754.png?v=1788495567"},{"product_id":"deye-sun-6k-sg05lp1-hybrid-inverter-1-faset","title":"Deye SUN-6K-SG05LP1-EU-AM2-P hybrid inverter 6 kW 1-phase","description":"\u003ch2\u003eDeye SUN-6K-SG05LP1-EU-AM2-P hybrid inverter 6 kW 1-phase – solar inverter, battery charger and emergency power supply in one unit.\u003c\/h2\u003e\u003cp\u003eThe Deye SUN-6K-SG05LP1-EU-AM2-P is a 6 kW 1-phase hybrid inverter that combines a solar inverter, battery charger, and emergency power supply into one unit. With 2 MPPT trackers and up to 12,000 W of connected solar power, it can both work in tandem with the grid and provide backup power to the house if the electricity goes out. This means you can store your own solar energy in the battery and use it when you actually need it – instead of selling it cheaply to the grid.\u003c\/p\u003e\u003ch3\u003eBenefits\u003c\/h3\u003e\u003cul\u003e\n\n\u003cli\u003eRated power 6,000 W\u003c\/li\u003e\n\n\u003cli\u003e2 independent MPPT trackers for flexible string configuration\u003c\/li\u003e\n\n\u003cli\u003eUp to 12,000 W solar power capacity can be connected\u003c\/li\u003e\n\n\u003cli\u003eMax. charge\/discharge current 135 A to battery\u003c\/li\u003e\n\n\u003cli\u003ePeak power in off-grid operation: 2 × rated power for 10 s\u003c\/li\u003e\n\n\u003cli\u003eEfficiency up to 97.6%\u003c\/li\u003e\n\n\u003cli\u003eProtection class IP65 – suitable for outdoor installation\u003c\/li\u003e\n\n\u003cli\u003eBuilt-in LCD display for local operation and monitoring\u003c\/li\u003e\n\n\u003cli\u003eCommunication via WiFi, RS485, CAN\u003c\/li\u003e\n\n\u003cli\u003eReady for remote monitoring via Deye Cloud \/ SOLARMAN (requires data logger)\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003ch3\u003eApplication\u003c\/h3\u003e\u003cul\u003e\n\n\u003cli\u003eSolar power systems with battery storage for private homes and small businesses\u003c\/li\u003e\n\n\u003cli\u003eUpgrading existing solar power systems with a battery (AC or DC coupled)\u003c\/li\u003e\n\n\u003cli\u003eEmergency power and backup during power outages\u003c\/li\u003e\n\n\u003cli\u003eLoad shifting – charge the battery when power is cheap and use it when prices peak\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eBattery type\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eLead-acid or lithium-ion\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eBattery voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e40-60 V\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. charge\/discharge current\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e135 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eCharging strategy for lithium battery\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eAutomatic adaptation to BMS\u003c\/td\u003e\n\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eNumber of battery inputs\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e1\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. connected PV power\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e12,000 W\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. PV input power\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e9,600 W\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. PV input voltage\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e500 V\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eStart-up voltage\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e125 V\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMPPT voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e150-425 V\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eRated PV input voltage\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e370 V\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. PV operating current\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e18+18 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. short-circuit current, input\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e27+27 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eNumber of MPPT \/ strings per MPPT\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e2\/1+1\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eRated AC input\/output power\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e6,000 W\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. AC input\/output power (VA)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e6,600 VA\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eRated AC input\/output current\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e27.3\/26.1 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. AC input\/output current\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e30\/28.7 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. continuous AC pass-through (grid to load)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e40 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003ePeak power (off-grid)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e2 × rated power for 10 s\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eRated input\/output voltage\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e220V\/230V 0.85Un-1.1Un L+N+PE\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eRated grid frequency \/ range\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e50\/45-55, 60\/55-65 Hz\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003ePower factor, adjustment range\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e0.8 leading – 0.8 lagging\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eHarmonic current distortion (THDi)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e\u0026lt;3% (of rated power)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eDC injection current\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e\u0026lt;0.5%ln\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. efficiency\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e97.6%\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eEuro-efficiency\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e96.5%\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMPPT efficiency\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e\u0026gt;99%\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eBuilt-in protection\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eReverse DC polarity protection, AC output overcurrent protection, thermal protection, AC output overvoltage protection, AC output short-circuit protection, DC component monitoring, arc fault detection (AFCI) (optional), anti-islanding protection, DC switch, insulation monitoring, residual current monitoring\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eSurge protection\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eType II (DC), Type II (AC)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eLCD display\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eCommunication interface\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eWiFi, RS485, CAN\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e-40 to +60°C, \u0026gt;45°C derating\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003ePermissible humidity\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e0~100%\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. installation altitude\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e2,000 m\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eNoise level\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e\u0026lt;45 dB\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eProtection class (IP)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eIP65\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eInverter topology\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eNon-isolated (solar), isolated (battery)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eOvervoltage category\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eOVC II (DC), OVC III (AC)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eDimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e330×580×232 (excl. connectors and brackets)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e24.9 kg\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e5 years \/ 10 years (warranty period depends on the inverter installation site – see Deye’s warranty policy)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eCooling\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eIntelligent air cooling\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eGrid standards\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eIEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eSafety \/ EMC standards\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eIEC\/EN 61000-6-1\/2\/3\/4, IEC\/EN 62109-1, IEC\/EN 62109-2\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eItem number: SUN-6K-SG05LP1-EU-AM2-P\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/www.deyeinverter.com\/deyeinverter\/2026\/04\/24\/BDatasheetSUN-36-10K-SG05LP1-EU-AM2-P20260424en-7f2j.pdf\" target=\"_blank\" rel=\"noopener\"\u003eDownload datasheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/www.deyeinverter.com\/product\/single-phase-low-voltage-hybrid-inverter\/sun3-6-5-6-7-7-6-8-10ksg05lp1euam2p-3-610kw-single-phase-2-mppt-hybrid-inverter-lv-battery-supported.html\" target=\"_blank\" rel=\"noopener\"\u003eOfficial product page at Deye\u003c\/a\u003e\u003c\/p\u003e","brand":"Deye","offers":[{"title":"Default Title","offer_id":65807943729501,"sku":"SUN-6K-SG05LP1-EU-AM2-P","price":7899.0,"currency_code":"DKK","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1022\/7649\/7757\/files\/SUN-3.6-10K-SG05LP1-EU_376d181d-2498-4375-a37c-cd01cd675927.png?v=1788495568"},{"product_id":"deye-sun-10k-sg02lp1-hybrid-inverter-1-faset","title":"Deye SUN-10K-SG02LP1-EU-AM3 hybrid inverter 10 kW 1-phase","description":"\u003ch2\u003eDeye SUN-10K-SG02LP1-EU-AM3 hybrid inverter 10 kW single-phase – solar inverter, battery charger, and emergency power in one unit.\u003c\/h2\u003e\u003cp\u003eThe Deye SUN-10K-SG02LP1-EU-AM3 is a 10 kW single-phase hybrid inverter that combines a solar inverter, battery charger, and emergency power supply into one unit. With 3 MPPT trackers and up to 20,000 W of connected solar capacity, it can both work in tandem with the grid and continue to power the house if the electricity goes out. This means you store your own solar energy in the battery and use it when you actually need it – instead of selling it cheaply to the grid.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\n\u003cli\u003eNominal power 10,000 W\u003c\/li\u003e\n\n\u003cli\u003e3 independent MPPT trackers for flexible string configuration\u003c\/li\u003e\n\n\u003cli\u003eUp to 20,000 W solar capacity can be connected\u003c\/li\u003e\n\n\u003cli\u003eMax. charging\/discharging current 220 A to the battery\u003c\/li\u003e\n\n\u003cli\u003ePeak power in off-grid mode: 2 × nominal power for 10 s\u003c\/li\u003e\n\n\u003cli\u003eEfficiency up to 97.6 %\u003c\/li\u003e\n\n\u003cli\u003eProtection class IP65 – suitable for outdoor installation\u003c\/li\u003e\n\n\u003cli\u003eCommunication via RS485\/RS232\/CAN\u003c\/li\u003e\n\n\u003cli\u003eReady for remote monitoring via Deye Cloud \/ SOLARMAN (requires data logger)\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003ch3\u003eApplication\u003c\/h3\u003e\u003cul\u003e\n\n\u003cli\u003eSolar power systems with battery storage for private homes and small businesses\u003c\/li\u003e\n\n\u003cli\u003eUpgrading existing solar systems with a battery (AC- or DC-coupled)\u003c\/li\u003e\n\n\u003cli\u003eEmergency power and backup during power outages\u003c\/li\u003e\n\n\u003cli\u003eLoad shifting – charge the battery when electricity is cheap, and use it when the price peaks\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eBattery type\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eLead-acid or lithium-ion\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eBattery voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e40-60 V\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. charging current\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e220 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. discharging current\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e220 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eCharging strategy for lithium battery\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eAutomatic adaptation to BMS\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eNumber of battery inputs\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e1\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. connected PV power\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e20,000 W\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. DC input power\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e16,000 W\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. DC input voltage\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e500 V\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eStart-up voltage\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e125 V\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMPPT voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e150-425 V\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eNominal DC input voltage\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e370 V\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. PV operating current\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e26+26+26 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. short-circuit current, input\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e44+44+44 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eNumber of MPPT \/ strings per MPPT\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e3\/2+2+2\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eNominal AC input\/output power\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e10,000 W\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. AC input\/output power (VA)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e11,000 VA\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003ePeak power (off-grid)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e2 × nominal power for 10 s\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eNominal AC input\/output current\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e45.5\/43.5 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. AC input\/output current\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e45.5\/43.5 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. continuous AC pass-through (grid to load)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e60 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003ePower factor, adjustment range\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e0.8 leading to 0.8 lagging\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eNominal input\/output voltage\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e220\/230 0.85Un-1.1Un\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eNominal grid frequency \/ range\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e50\/45-55, 60\/55-65 Hz\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eGrid connection\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eL+N+PE\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eTotal harmonic distortion (THDi)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e\u0026lt;3 % (of nominal power)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eDC injection current\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e\u0026lt;0.5 %ln\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. efficiency\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e97.6 %\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eEuro efficiency\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e96.5 %\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMPPT efficiency\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e\u0026gt;99 %\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eBuilt-in protection\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eReverse DC polarity protection, AC output overcurrent protection, thermal protection, AC output overvoltage protection, AC output short-circuit protection, DC component monitoring, arc fault detection (AFCI) (optional), anti-islanding protection, DC switch, insulation monitoring, residual current monitoring\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eSurge protection\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eType II(DC), Type II(AC)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eCommunication interface\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eRS485\/RS232\/CAN\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMonitoring\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eGPRS\/WiFi\/Bluetooth\/4G\/LAN (optional)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e-40 to +60°C, \u0026gt;45°C power derating\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003ePermissible humidity\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e0~100 %\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. installation altitude\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e2,000m\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eNoise level\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e\u0026lt;45\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eProtection class (IP)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eIP65\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eInverter topology\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eNon-isolated\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eOvervoltage category\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eOVC II(DC), OVC IV(AC)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eDimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e420×670×233 (excl. connectors and brackets)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e35.6 kg\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e5 years \/ 10 years (warranty period depends on the inverter's installation location – see Deye's warranty policy)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eCooling\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eIntelligent air cooling\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eGrid standards\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eVDE4105, IEC61727\/62116, VDE0126, AS4777.2, CEI 0 21, EN50549-1, G98, G99, C10-11, UNE217002, NBR16149\/NBR16150\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eSafety \/ EMC standards\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eIEC\/EN 61000-6-1\/2\/3\/4, IEC\/EN 62109-1, IEC\/EN 62109-2\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eItem number: SUN-10K-SG02LP1-EU-AM3\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/www.deyeinverter.com\/deyeinverter\/2025\/05\/29\/%E3%80%90b%E3%80%91datasheet_sun-7.6-12k-sg02lp1-eu-am2_30240102201653_20250520_en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eDownload datasheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/www.deyeinverter.com\/product\/single-phase-low-voltage-hybrid-inverter\/sun7-6-8-10-12ksg02lp1euam2-am3-7-612kw-single-phase-2-mppt-hybrid-inverter-lv-battery-supported.html\" target=\"_blank\" rel=\"noopener\"\u003eOfficial product page at Deye\u003c\/a\u003e\u003c\/p\u003e","brand":"Deye","offers":[{"title":"Default Title","offer_id":65807943827805,"sku":"SUN-10K-SG02LP1-EU-AM3","price":15499.0,"currency_code":"DKK","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1022\/7649\/7757\/files\/101_9738ea6d-6512-4f7c-b98b-f71918b377ba.png?v=1788495569"},{"product_id":"deye-sun-16k-sg01lp1-eu-hybrid-inverter-16-kw-1-faset","title":"Deye SUN-16K- SG01LP1-EU hybrid inverter 16 kW 1-phase","description":"\u003ch2\u003eDeye SUN-16K -SG01LP1-EU hybrid inverter 16 kW 1-phase – PV inverter, battery charger and emergency power in one unit.\u003c\/h2\u003e\u003cp\u003eThe Deye SUN-16K-SG01LP1-EU is a 16 kW 1-phase hybrid inverter that combines a solar PV inverter, battery charger, and emergency power supply in one unit. With 3 MPPT trackers and up to 32,000 W of connected solar power, it can both work in tandem with the power grid and continue to supply power to the house if the grid goes down. This means you store your own solar energy in the battery and use it when you actually need it – instead of selling it cheaply to the grid.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\n\u003cli\u003eNominal power 16,000 W\u003c\/li\u003e\n\n\u003cli\u003e3 independent MPPT trackers for flexible string configuration\u003c\/li\u003e\n\n\u003cli\u003eUp to 32,000 W of solar power can be connected\u003c\/li\u003e\n\n\u003cli\u003eMax. charge\/discharge current 290 A to the battery\u003c\/li\u003e\n\n\u003cli\u003ePeak power in off-grid mode: 2 × nominal power for 10 s\u003c\/li\u003e\n\n\u003cli\u003eEfficiency up to 97.6%\u003c\/li\u003e\n\n\u003cli\u003eIngress protection rating IP65 – can be mounted outdoors\u003c\/li\u003e\n\n\u003cli\u003eBuilt-in LCD display for local operation and monitoring\u003c\/li\u003e\n\n\u003cli\u003eCommunication via WiFi, RS485, CAN\u003c\/li\u003e\n\n\u003cli\u003eReady for remote monitoring via Deye Cloud \/ SOLARMAN (requires data logger)\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\n\u003cli\u003eSolar power systems with battery storage for private homes and small businesses\u003c\/li\u003e\n\n\u003cli\u003eUpgrading existing solar power systems with a battery (AC- or DC-coupled)\u003c\/li\u003e\n\n\u003cli\u003eEmergency power and backup in case of power failure\u003c\/li\u003e\n\n\u003cli\u003eLoad shifting – charge the battery when power is cheap and use it when prices peak\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eBattery type\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eLead-acid or lithium-ion\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eBattery voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e40-60 V\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. charge\/discharge current\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e290 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eCharging strategy for lithium battery\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eAutomatic adaptation to BMS\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eNumber of battery inputs\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e1\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. connected PV power\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e32,000 W\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. PV input power\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e25,600 W\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. PV input voltage\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e500 V\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eStart-up voltage\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e125 V\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMPPT voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e150-425 V\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eNominal PV input voltage\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e370 V\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. PV operating current\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e36+36+36 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. short-circuit current, input\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e54+54+54 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eNumber of MPPT \/ strings per MPPT\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e3\/2+2+2\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eNominal AC input\/output power\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e16,000 W\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. AC input\/output power (VA)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e17,600 VA\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eNominal AC input\/output current\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e72.8\/69.6 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. AC input\/output current\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e80\/76.6 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. continuous AC pass-through (grid to consumption)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e100 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003ePeak power (off-grid)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e2 × nominal power for 10 s\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003ePower factor, adjustment range\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e0.8 capacitive to 0.8 inductive\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eNominal input\/output voltage\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e220\/230V 0.85Un-1.1Un L+N+PE\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eNominal grid frequency \/ range\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e50\/45-55, 60\/55-65 Hz\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eHarmonic current distortion (THDi)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e\u0026lt;3% (at nominal power)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eDC injection current\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e\u0026lt;0.5%In\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. efficiency\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e97.6%\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eEuro efficiency\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e96.5%\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMPPT efficiency\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e＞99%\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eIntegrated protection\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eReverse DC polarity protection, AC output overcurrent protection, thermal protection, AC output overvoltage protection, AC output short-circuit protection, DC component monitoring, arc fault detection (AFCI) (optional), anti-islanding protection, DC switch, insulation monitoring, residual current monitoring\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eSurge protection\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eType II(DC), Type II(AC)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eLCD display\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eCommunication interface\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eWiFi, RS485, CAN\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e-40 to +60°C, \u0026gt;45°C power derating\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003ePermissible humidity\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e0~100%\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. installation altitude\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e3,000 m\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eNoise level\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e＜55 dB\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eIngress protection (IP)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eIP65\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eInverter topology\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eNon-isolated (PV), isolated (battery)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eOvervoltage category\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eOVC II(DC), OVC III(AC)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eDimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e464×763×282 (excl. connectors and brackets)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e54.1 kg\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e5 years \/ 10 years (warranty period depends on the inverter's installation location – see Deye's warranty policy)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eCooling\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eIntelligent air cooling\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eGrid standards\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eIEC 61727, IEC 62116, AS 4777.2, NRS 097\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eSafety \/ EMC standards\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eIEC\/EN 61000-6-1\/2\/3\/4, IEC\/EN 62109-1, IEC\/EN 62109-2\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eItem number: SUN-16K-SG01LP1-EU\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/www.deyeinverter.com\/deyeinverter\/2026\/08\/10\/BDatasheetSUN-12-18K-SG01LP1-EU-AM3-P20260810en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eDownload datasheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/www.deyeinverter.com\/product\/single-phase-low-voltage-hybrid-inverter\/sun12-14-16-18ksg01lp1euam3p.html\" target=\"_blank\" rel=\"noopener\"\u003eOfficial product page at Deye\u003c\/a\u003e\u003c\/p\u003e","brand":"Deye","offers":[{"title":"Default Title","offer_id":65807943860573,"sku":"SUN-16K-SG01LP1-EU","price":19299.0,"currency_code":"DKK","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1022\/7649\/7757\/files\/12-18.png?v=1788495568"},{"product_id":"deye-sun-12k-sg02lp1-hybrid-inverter-1-faset","title":"Deye SUN-12K-SG02LP1-EU-AM3 hybrid inverter 12 kW 1-phase","description":"\u003ch2\u003eDeye SUN-12K-SG02LP1-EU-AM3 hybrid inverter 12 kW 1-phase – solar inverter, battery charger, and emergency power in one unit.\u003c\/h2\u003e\u003cp\u003eThe Deye SUN-12K-SG02LP1-EU-AM3 is a 12 kW 1-phase hybrid inverter that combines a solar inverter, battery charger, and emergency power supply in one unit. With 3 MPPT trackers and up to 24,000 W of connected solar power, it can both work in tandem with the electrical grid and continue to power the house if the power goes out. This means you store your own solar energy in the battery and use it when you actually need it – instead of selling it cheaply to the grid.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\n\u003cli\u003eNominal power 12,000 W\u003c\/li\u003e\n\n\u003cli\u003e3 independent MPPT trackers for flexible string configuration\u003c\/li\u003e\n\n\u003cli\u003eUp to 24,000 W of solar power can be connected\u003c\/li\u003e\n\n\u003cli\u003eMax. charging\/discharging current 250 A for the battery\u003c\/li\u003e\n\n\u003cli\u003ePeak power in off-grid mode: 2 × nominal power for 10 s\u003c\/li\u003e\n\n\u003cli\u003eEfficiency up to 97.6 %\u003c\/li\u003e\n\n\u003cli\u003eIngress protection IP65 – can be mounted outdoors\u003c\/li\u003e\n\n\u003cli\u003eCommunication via RS485\/RS232\/CAN\u003c\/li\u003e\n\n\u003cli\u003eReady for remote monitoring via Deye Cloud \/ SOLARMAN (requires data logger)\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003ch3\u003eApplication\u003c\/h3\u003e\u003cul\u003e\n\n\u003cli\u003eSolar power systems with battery storage for private homes and small businesses\u003c\/li\u003e\n\n\u003cli\u003eUpgrading existing solar installations with a battery (AC or DC coupled)\u003c\/li\u003e\n\n\u003cli\u003eEmergency power and backup during power outages\u003c\/li\u003e\n\n\u003cli\u003eLoad shifting – charge the battery when power is cheap and use it when prices peak\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eBattery type\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eLead-acid or lithium-ion\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eBattery voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e40-60 V\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. charging current\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e250 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. discharging current\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e250 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eCharging strategy for lithium battery\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eAutomatic adaptation to BMS\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eNumber of battery inputs\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e1\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. connected PV power\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e24,000 W\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. DC input power\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e19,200 W\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e \u003cstrong\u003eMax. DC input voltage\u003c\/strong\u003e\n\u003c\/td\u003e\n\n\u003ctd\u003e500 V\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eStart voltage\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e125 V\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMPPT voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e150-425 V\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eNominal DC input voltage\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e370 V\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. PV operating current\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e26+26+26 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. short-circuit current, input\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e44+44+44 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eNumber of MPPT \/ strings per MPPT\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e3\/2+2+2\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eNominal AC input\/output power\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e12,000 W\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. AC input\/output power (VA)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e13,200 VA\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003ePeak power (off-grid)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e2 × nominal power for 10 s\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eNominal AC input\/output current\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e54.6\/52.2 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. AC input\/output current\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e54.6\/52.2 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. continuous AC pass-through (grid to load)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e60 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003ePower factor, adjustment range\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e0.8 capacitive to 0.8 inductive\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eNominal input\/output voltage\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e220\/230 0.85Un-1.1Un\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eNominal grid frequency \/ range\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e50\/45-55, 60\/55-65 Hz\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eGrid connection\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eL+N+PE\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eHarmonic current distortion (THDi)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e\u0026lt;3 % (of nominal power)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eDC injection current\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e\u0026lt;0.5 %ln\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. efficiency\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e97.6 %\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eEuro efficiency\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e96.5 %\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMPPT efficiency\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e＞99 %\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eBuilt-in protection\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003ereverse DC polarity protection, AC output overcurrent protection, thermal protection, AC output overvoltage protection, AC output short-circuit protection, DC component monitoring, arc fault detection (AFCI) (optional), anti-islanding protection, DC switch, insulation monitoring, residual current monitoring\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eSurge protection\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eType II(DC), Type II(AC)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eCommunication interface\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eRS485\/RS232\/CAN\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMonitoring\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eGPRS\/WiFi\/Bluetooth\/4G\/LAN (optional)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e-40 to +60°C, \u0026gt;45°C power derating\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003ePermissible humidity\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e0~100 %\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. installation altitude\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e2,000m\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eNoise level\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e＜45\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eIngress protection (IP)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eIP65\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eInverter topology\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eNon-isolated\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eOvervoltage category\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eOVC II(DC), OVC IV(AC)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eDimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e420×670×233 (excl. connectors and brackets)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e35.6 kg\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e5 years \/ 10 years (warranty period depends on the inverter installation site – see Deye's warranty policy)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eCooling\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eIntelligent air cooling\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eGrid standards\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eVDE4105, IEC61727\/62116, VDE0126, AS4777.2, CEI 0 21, EN50549-1, G98, G99, C10-11, UNE217002, NBR16149\/NBR16150\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eSafety \/ EMC standards\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eIEC\/EN 61000-6-1\/2\/3\/4, IEC\/EN 62109-1, IEC\/EN 62109-2\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eItem number: SUN-12K-SG02LP1-EU-AM3\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/www.deyeinverter.com\/deyeinverter\/2025\/05\/29\/%E3%80%90b%E3%80%91datasheet_sun-7.6-12k-sg02lp1-eu-am2_30240102201653_20250520_en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eDownload datasheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/www.deyeinverter.com\/product\/single-phase-low-voltage-hybrid-inverter\/sun7-6-8-10-12ksg02lp1euam2-am3-7-612kw-single-phase-2-mppt-hybrid-inverter-lv-battery-supported.html\" target=\"_blank\" rel=\"noopener\"\u003eOfficial product page at Deye\u003c\/a\u003e\u003c\/p\u003e","brand":"Deye","offers":[{"title":"Default Title","offer_id":65807943893341,"sku":"SUN-12K-SG02LP1-EU-AM3","price":16199.0,"currency_code":"DKK","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1022\/7649\/7757\/files\/101.png?v=1788495569"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1022\/7649\/7757\/collections\/101.png?v=1790086922","url":"https:\/\/lithiumpro.dk\/en\/collections\/deye-hybrid-invertere-1-faset.oembed","provider":"LithiumPro","version":"1.0","type":"link"}